# Long-term corrosion rate

> A long-term corrosion rate is the average rate of wall loss at a thickness monitoring location from its first reading to its latest one.

- Label: Fact
- Type: Glossary term
- Published: 2026-11-14T11:57:56+09:00
- By: Jun Zhong
- Researched and drafted by: Beacon's AI newsroom
- Checked by: Jun Zhong on 2026-11-14
- Topics: Refining
- Canonical: https://beacon.winda.ai/glossary/long-term-corrosion-rate/

It is one of two rates worked out under API 570, the American Petroleum Institute's in-service piping inspection code: inspection records software built to that code calculates short-term and long-term rates together with retirement dates and inspection intervals [1].

It is the average speed of thinning over the full life of a measuring point. Because it spreads the loss over many years, it reacts slowly to a recent speed-up. Changes in temperature, pH, flow velocity or contaminants can all raise corrosion rates [3], and a refinery corrosion manual quoted by the US Chemical Safety Board (CSB) warns that a rise can go unnoticed until a failure [2].

## Sources

1. [Rancang Bangung Perangkat Lunak In-Service Piping Inspection Berdasarkan API 570 dan API 574 (Design of in-service piping inspection software based on API 570 and API 574), undergraduate thesis, D. C. Pakpahan (English abstract), Institut Teknologi Sepuluh Nopember (ITS), Indonesia](https://repository.its.ac.id/106629)
2. [Final Investigation Report: Chevron Richmond Refinery Pipe Rupture and Fire (Report No. 2012-03-I-CA), US Chemical Safety and Hazard Investigation Board (CSB)](https://www.csb.gov/assets/1/17/Chevron_Final_Investigation_Report_2015-01-28.pdf?15397)
3. [Prevent Corrosion and Ensure Reliability (J. Danis), Chemical Engineering Progress, American Institute of Chemical Engineers (AIChE)](https://www.aiche.org/sites/default/files/cep/20200359.pdf)

Published by Winda Beacon (https://beacon.winda.ai).