# Pipe-to-soil potential

> Pipe-to-soil potential is the voltage between a buried pipe and the soil around it, measured against a reference electrode placed in contact with the soil.

- Label: Fact
- Type: Glossary term
- Published: 2026-11-13T09:39:01+09:00
- By: Jun Zhong
- Researched and drafted by: Beacon's AI newsroom
- Checked by: Jun Zhong on 2026-11-13
- Topics: Pipelines, Upstream and offshore
- Canonical: https://beacon.winda.ai/glossary/pipe-to-soil-potential/

It is the main reading used to judge cathodic protection: one criterion for steel in Appendix D to 49 CFR Part 192 is at least 0.85 volt negative against a saturated copper-copper sulfate half cell, measured with protective current on and allowing for voltage drops other than across the pipe-soil boundary [2]. Hazardous liquid pipelines use criteria from NACE SP0169, incorporated by reference (49 CFR 195.571) [4].

It is a voltmeter reading between the pipe and a reference probe on the ground, showing whether protective current reaches the pipe. On onshore gas transmission lines, a low annual test station reading requires the operator to find how far the weak protection extends, where needed by surveys at about 5-foot spacing (49 CFR 192.465(f)) [1][3].

## Sources

1. [TM 5-811-7, Electrical Design, Cathodic Protection (Technical Manual), Headquarters, US Department of the Army (hosted by the Whole Building Design Guide)](https://www.wbdg.org/FFC/ARMYCOE/COETM/tm_5_811_7.pdf), 1985-04-22
2. [Appendix D to Part 192, Criteria for Cathodic Protection and Determination of Measurements, eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-49/chapter-I/subchapter-D/part-192/appendix-Appendix%20D%20to%20Part%20192)
3. [49 CFR Part 192, Subpart I, Requirements for Corrosion Control (192.465 Monitoring and remediation), eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-49/chapter-I/subchapter-D/part-192/subpart-I)
4. [49 CFR Part 195, Subpart H, Corrosion Control (195.553 special definitions; 195.571 criteria for cathodic protection), eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-49/chapter-I/subchapter-D/part-195/subpart-H)

Published by Winda Beacon (https://beacon.winda.ai).