# How are biocides used to control microbiologically influenced corrosion?

> Biocides are chemicals that kill or suppress the microorganisms behind microbiologically influenced corrosion (MIC) in water-bearing oil and gas systems. Oxidizing and non-oxidizing types are dosed into the fluid, often alongside mechanical cleaning and monitoring. In the US, such products must be registered as pesticides with the Environmental Protection Agency (40 CFR 152.15).

- Label: Fact
- Type: Explainer
- Published: 2026-11-14T11:53:52+09:00
- By: Jun Zhong
- Researched and drafted by: Beacon's AI newsroom
- Checked by: Jun Zhong on 2026-11-14
- Topics: Pipelines, Upstream and offshore
- Canonical: https://beacon.winda.ai/library/biocides-for-mic/

## Why does it matter?

As molecular testing spread, asset owners found microorganisms almost everywhere in their systems, but cell counts correlated poorly with actual MIC damage, according to a 2023 review [2]. The same review notes that microbes living in a biofilm on the wall can tolerate treatment far better than free-floating cells, in an extreme case about 1,000 times better [2]. A biocide program therefore has to be judged by what happens at the metal surface, not only by bacteria counts in a water sample [2].

## How do biocides control MIC?

MIC is corrosion accelerated by microorganisms and their products, which mostly live in biofilms: layers of cells held together by a slime of sugars, proteins and other substances they secrete [1]. The corrosion glossary of the UK National Physical Laboratory (NPL) defines a biocide simply as an added chemical whose job is to kill living things [11]. Biocides attack cell membranes and enzymes, killing the microbes and breaking down biofilm [1]. A 2023 review by Shi and co-authors describes them as the most cost-effective MIC control in practice [1].

They are one option among several. Knisz and co-authors list biocides alongside corrosion inhibitors, oxygen scavengers, flow velocity control, pigging or flushing, ultraviolet treatment, separators and filters, and control of fluid quality [2]. In some oilfields, nitrate is added so that nitrate-reducing bacteria outcompete the sulfate-reducing bacteria that produce hydrogen sulfide (H2S) [1][2]. Corrosion inhibitors on their own do not control MIC: the UK Health and Safety Executive (HSE) finds them ineffective against it [3].

## Which biocides are used?

| Class | Generic examples | How it acts | Limits reported |
|---|---|---|---|
| Oxidizing | Chlorine, sodium hypochlorite, chlorine dioxide, bromine compounds, ozone, hydrogen peroxide | Oxidizes membranes, enzymes and biofilm material | Reacts with organic matter, so the effect is unstable; excess can raise metal corrosion; little effect on biofilm formation |
| Aldehydes | Glutaraldehyde (the most common) | Enters cells and binds proteins | Toxic |
| Quaternary ammonium compounds | Single, twin-headed and polymeric forms | Positive charge binds the cell wall and damages the membrane; some also inhibit corrosion | Long use can breed resistance |
| Quaternary phosphonium salts | Tetrakis(hydroxymethyl)phosphonium sulfate (THPS), the most common in oilfields | Similar to quaternary ammonium | Too low a dose can stimulate growth in the biofilm |
| Heterocyclic compounds | Isothiazolinones | Block the cell's energy supply and damage DNA | React with H2S, so unsuitable for sulfide-bearing injection water; low doses can increase growth |
| Organobromine compounds | Non-oxidizing bromine-containing biocides | Efficient, broad-spectrum killing | Some breakdown products are more toxic or persistent than the parent |

Source: Shi et al., 2023 [1]. Generic chemical classes only; no products or suppliers are named.

## How are biocides applied?

- **Continuously or repeatedly.** Industrial systems keep receiving new microbes, so a single treatment cannot eradicate them and control requires continuing doses [1].
- **At an effective dose.** Cells in biofilms need higher concentrations than free cells, and doses that are too low can stimulate growth [1].
- **Varied over time.** Using the same biocide for a long time promotes resistance and rising doses, and excess use can cause scaling [1]. Mixing biocides, or adding enhancers such as chelating agents or D-amino acids, can lower the dose needed [1].
- **With cleaning.** Pigging and flushing remove biofilm and deposits but do not stop regrowth; in seawater a biofilm can form within minutes [2]. Mechanical cleaning can also spread microbes from damaged biofilm, so it is often paired with chemicals [1].

In the US, a product intended to protect industrial processes, systems or water from fouling or deterioration caused by bacteria and other microbes is an antimicrobial pesticide [5], and no one may distribute or sell a pesticide that is not registered under the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) (40 CFR 152.15) [6]. The Environmental Protection Agency (EPA) groups cooling tower and jet fuel treatments among non-public-health antimicrobial uses [4]. In the European Union, coatings that release biocides are regulated under the Biocides Regulation [2].

## How is a biocide program judged to work?

Knisz and co-authors describe corrosion management as a repeating cycle of threat assessment, mitigation and monitoring, in which microbiological data are read together with coupons, probes, inspection results, operating conditions and fluid chemistry [2]. No single test proves MIC, so investigators combine multiple lines of evidence [2]. Molecular microbiological methods help show whether a new treatment changes the types, numbers and activity of microbes where corrosion occurs, but collecting biofilm samples from a working asset and analyzing them before genetic information degrades is a main practical difficulty [2]. Where nitrate is injected, sulfate, sulfide, nitrate and nitrite are monitored closely to set doses [2].

## Where integrity problems show up

| Where it occurs (unit or equipment) | Conditions that drive it | How it is usually found | In the Library |
|---|---|---|---|
| Low point downstream of a partly clogged drip [7] | Microbes with water, chlorides, oxygen, carbon dioxide and H2S; liquids bypassed the drip and cleaning pigs could not run [7] | Microbial tests of deposits from scrubbers, drips and pig receivers; coupons and in-line inspection [7] | [What is microbiologically influenced corrosion (MIC)?](/library/microbiologically-influenced-corrosion/) |
| Dead legs and piping with no flow or stratified flow | Water and solids settle and biofilms grow [2] | Design and operating records reviewed to find such areas and target inspection [2] | [Dead leg](/glossary/dead-leg/) |
| Deposits and biofilm in water-handling lines | Sessile cells tolerate biocide; low doses can stimulate growth [1][2] | Coupons and probes with biofilm sampling and molecular methods [2] | [What is under-deposit corrosion?](/library/under-deposit-corrosion/) |
| Buried pipe in waterlogged, airless clay | Sulfate-reducing bacteria active without oxygen [8]; NPL calls for a more negative cathodic protection potential on steel where they are present [9] | On excavation, black product smelling of H2S over a shiny surface; tests for anaerobic or corrosion-accelerating bacteria [8][10] | [What is soil corrosion?](/library/soil-corrosion/) |

Sources: NTSB PAR-03/01 [7]; Knisz et al., 2023 [2]; Shi et al., 2023 [1]; NPL Guide No. 4 [8]; 49 CFR 192.455 [10].

## Sources

1. [Comprehensive Review on the Use of Biocides in Microbiologically Influenced Corrosion (X. Shi, R. Zhang, W. Sand and others), Microorganisms 11(9):2194, MDPI (open access, CC BY 4.0)](https://pmc.ncbi.nlm.nih.gov/articles/PMC10535546/), 2023-08-30
2. [Microbiologically influenced corrosion: more than just microorganisms (J. Knisz, R. Eckert, L. M. Gieg and others), FEMS Microbiology Reviews 47(5):fuad041, Oxford University Press on behalf of FEMS (open access, CC BY 4.0)](https://pmc.ncbi.nlm.nih.gov/articles/PMC10479746/)
3. [RR1023: Reliable corrosion inhibition in the oil and gas industry (J. Hobbs, Health and Safety Laboratory, 2014; archived copy, withdrawn from hse.gov.uk), UK Health and Safety Executive (HSE)](http://web.archive.org/web/20240809100026id_/https://www.hse.gov.uk/research/rrpdf/rr1023.pdf)
4. [What are Antimicrobial Pesticides?, US Environmental Protection Agency (EPA)](https://www.epa.gov/pesticide-registration/what-are-antimicrobial-pesticides)
5. [Antimicrobial Pesticide Registration, US Environmental Protection Agency (EPA)](https://www.epa.gov/pesticide-registration/antimicrobial-pesticide-registration)
6. [40 CFR 152.15, Pesticide products required to be registered (with 152.3 definitions), eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-40/section-152.15)
7. [Pipeline Accident Report NTSB/PAR-03/01: Natural Gas Pipeline Rupture and Fire Near Carlsbad, New Mexico, August 19, 2000, US National Transportation Safety Board (NTSB)](https://www.ntsb.gov/investigations/AccidentReports/Reports/PAR0301.pdf)
8. [Guides to Good Practice in Corrosion Control No. 4: Corrosion Control for Buried Pipelines (D. W. Harvey), National Physical Laboratory (NPL), UK](https://eprintspublications.npl.co.uk/8622/1/Corrosion%20Guide%20No%204.pdf)
9. [Guides to Good Practice in Corrosion Control No. 1: Cathodic Protection (D. W. Harvey), National Physical Laboratory (NPL), UK](https://eprintspublications.npl.co.uk/8402/1/Corrosion%20Guide%20No%201.pdf)
10. [49 CFR 192.455, External corrosion control: Buried or submerged pipelines installed after July 31, 1971 (Part 192, Subpart I), eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-49/chapter-I/subchapter-D/part-192/subpart-I)
11. [Guides to Good Practice in Corrosion Control No. 11: Corrosion control checklist, National Physical Laboratory (NPL), UK](https://eprintspublications.npl.co.uk/8621/1/Corrosion%20Guide%20No%2011.pdf)

Published by Winda Beacon (https://beacon.winda.ai).