# What is a fired heater?

> A fired heater is a furnace that burns fuel to heat a process fluid flowing through tubes, usually in a radiant firebox and a convection section. Refineries use them to preheat crude, coker and hydrotreater feeds. API Standard 560 covers their design and construction for general refinery service, and API Recommended Practice 573 covers inspection.

- Label: Fact
- Type: Explainer
- Published: 2026-11-13T15:18:43+09:00
- By: Jun Zhong
- Researched and drafted by: Beacon's AI newsroom
- Checked by: Jun Zhong on 2026-11-13
- Topics: Refining
- Canonical: https://beacon.winda.ai/library/fired-heater/

## How does a fired heater work?

Burners release heat in a refractory-lined box called the firebox or radiant section, where tubes along the walls pick up heat mainly by radiation from the flames and hot gas [2][3][8]. The flue gas then passes through a convection section, where it heats more tubes by contact; these tubes often carry fins or studs to add surface area [2]. A few rows of bare shield tubes sit between the two sections and take the direct radiation so the finned tubes are not overheated [2].

The process fluid usually enters through the convection tubes and finishes in the radiant tubes [2]. Flue gas leaves through the stack; its exit temperature is the main heat loss, and how far it can be cooled is limited by condensation of sulfuric acid [2]. Combustion air is drawn in by the natural draft of the stack or moved by forced-draft or induced-draft fans [2][8].

Refinery heaters burn refinery fuel gas, natural gas, distillates or residual oils [1]. AIChE notes that the hazard is greater than in other combustion equipment because the fluid inside the tubes is itself flammable [3].

## Where are fired heaters used?

| Unit | What the heater does | Approximate temperature given by OSHA |
|---|---|---|
| Crude distillation | Heats desalted crude before the atmospheric tower | 650 to 700 °F (343 to 371 °C) |
| Delayed coking | Heats heavy residue before the coke drums | 900 to 950 °F (482 to 510 °C) |
| Hydrotreating | Preheats feed before the reactor | 600 to 800 °F (316 to 427 °C) |
| Catalytic reforming | Preheats reformer feed | not stated |
| Large distillation columns | Serves as a fired reboiler | not stated |

Source: OSHA Technical Manual, Section IV, Chapter 2, checked October 2026 [1].

OSHA's manual notes two limits on these duties [1]. Overheating crude in the charge heater can start unwanted thermal cracking, and coker heaters are designed and run to avoid coke forming early inside the tubes, with water or steam injection sometimes used to limit it [1].

## What are the main types of fired heater?

Fired heaters are commonly grouped by the shape of the radiant section [2]. Box or cabin heaters have a rectangular firebox and suit large capacities and heat duties; cylindrical heaters have a vertical, round firebox, are common in hot oil service, heat more evenly and need smaller foundations [2]. Box heaters usually have horizontal radiant tubes and cylindrical heaters vertical ones [8]. Some heaters are all-radiant, with no separate convection section [2].

Not every furnace in a plant counts as a fired heater in the API sense. API Standard 560 excludes steam reformers and pyrolysis furnaces, such as those used to crack ethane, and API keeps a separate recommended practice, RP 538, for industrial fired boilers that make steam [4].

## Which standards and safety rules apply?

The American Petroleum Institute (API) publishes several documents for this equipment [4]. API 560 covers design, materials, fabrication, inspection, testing and erection of fired heaters, air preheaters, fans and burners for general refinery service; API 535 covers burners for API 560 heaters; API 536 covers post-combustion control of nitrogen oxides; and API RP 573 covers inspection of fired boilers and process heaters, both on-stream and off-stream [4].

Start-up is the riskiest moment. OSHA's manual states that heaters need enough draft or steam purging before light-off, and that losing a burner flame during light-off can let a flammable fuel and air mixture build up in the firebox [1]. The manual also calls for heater tubes to be fully depressured before headers or fittings are opened [1].

The US Chemical Safety and Hazard Investigation Board (CSB) issued its final report on 16 September 2026 on a 4 June 2025 explosion in an ethane cracking furnace at a petrochemical plant in Monaca, Pennsylvania [6][7]. Two isolation valves were opened at the same time, cracked gas flowed back from the quench tower into the firebox and ignited on the lit pilots; property damage was estimated at $95 million [7]. The CSB recommended an engineered control to stop backflow into the furnace in every operating mode, in place of reliance on administrative controls [6][7].

## Where integrity problems show up

| Heater part or condition | Typical integrity issue | In the Library |
|---|---|---|
| Crude heater tubes in sour crude service | Severe corrosion of furnace tubing where metal temperature exceeds about 450 °F (232 °C), from hydrogen sulfide and sulfur compounds | [What is sulfidation (high-temperature sulfur corrosion)?](/library/sulfidation/) |
| Vacuum heater tubes | Corrosion from hydrogen sulfide, sulfur compounds and organic acids | [What is naphthenic acid corrosion?](/library/naphthenic-acid-corrosion/) |
| Heater tubes fouled after poor desalting | Restricted flow and heat transfer, leading to failures from higher pressure and temperature | [What is short-term overheating of heater tubes?](/library/short-term-overheating/) |
| Convection section and stack | Sulfuric acid condensation when flue gas is cooled too far | What is flue gas dew point corrosion? |
| Firebox | Ignition of flammable gas that collects at light-off or flows back from the process | [What is a safety instrumented system (SIS)?](/library/safety-instrumented-system/) |
| Tube leaks in service | A crude heater tube leak that was not adequately evaluated, cited in OSHA's refinery inspections | What is mechanical integrity (MI)? |

Sources: OSHA Technical Manual, Section IV, Chapter 2 [1]; Al-Haj Ibrahim, 2010 [2]; OSHA 3918, 2017 [5]; CSB, 2026 [6][7].

## Sources

1. [OSHA Technical Manual, Section IV, Chapter 2: Petroleum Refining Processes, US Occupational Safety and Health Administration (OSHA)](https://www.osha.gov/otm/section-4-safety-hazards/chapter-2)
2. [Fired Process Heaters (H. Al-Haj Ibrahim, Al-Baath University; chapter in Matlab: Modelling, Programming and Simulations, IntechOpen), IntechOpen (copy on Academia.edu)](https://www.academia.edu/74444438/Fired_Process_Heaters)
3. [Fired Heater Safety: Common Failure Factors (Chemical Engineering Progress), American Institute of Chemical Engineers (AIChE)](https://aiche.org/resources/publications/cep/2021/may/fired-heater-safety-common-failure-factors)
4. [2025 Publications Catalog (Refining: Heat Transfer Equipment Standards; Inspection of Refinery Equipment), American Petroleum Institute (API)](https://www.api.org/-/media/files/publications/2025-catalog/2025_pubs%20catalog.pdf)
5. [Process Safety Management for Petroleum Refineries: Lessons Learned from the Petroleum Refinery Process Safety Management National Emphasis Program (OSHA 3918), US Occupational Safety and Health Administration (OSHA)](https://www.osha.gov/Publications/OSHA3918.pdf)
6. [Shell Polymers Furnace Explosion and Fire (investigation page), US Chemical Safety and Hazard Investigation Board (CSB)](https://www.csb.gov/shell-polymers-furnace-explosion-and-fire/)
7. [US Chemical Safety Board Releases Final Investigation Report on 2025 Explosion and Fire at Shell Polymers Monaca Facility in Pennsylvania, US Chemical Safety and Hazard Investigation Board (CSB)](https://www.csb.gov/us-chemical-safety-board-releases-final-investigation-report-on-2025-explosion-and-fire-at-shell-polymers-monaca-facility-in-pennsylvania/), 2026-09-16
8. [Fired heaters for dummies (E. Platvoet), Digital Refining (PTQ)](https://www.digitalrefining.com/article/1002765/fired-heaters-for-dummies)

Published by Winda Beacon (https://beacon.winda.ai).