# What is hydroprocessing (hydrotreating and hydrocracking)?

> Hydroprocessing is the group of refinery processes that react oil fractions with hydrogen over a catalyst at high temperature and pressure. Hydrotreating removes sulfur, nitrogen, oxygen and metals with little change in molecule size; hydrocracking also breaks heavy gas oils into diesel, jet fuel and naphtha. Hot hydrogen makes high temperature hydrogen attack a key integrity concern.

- Label: Fact
- Type: Explainer
- Published: 2026-11-13T09:39:01+09:00
- By: Jun Zhong
- Researched and drafted by: Beacon's AI newsroom
- Checked by: Jun Zhong on 2026-11-13
- Topics: Refining
- Canonical: https://beacon.winda.ai/library/hydroprocessing/

## What is the difference between hydrotreating and hydrocracking?

Both use hydrogen, a catalyst and high pressure [3][6]. The difference is the goal: hydrotreating removes impurities and keeps cracking to a minimum, whereas hydrocracking deliberately breaks heavy oil into lighter products [3][2].

| | Hydrotreating | Hydrocracking |
|---|---|---|
| Main purpose | Remove sulfur, nitrogen, oxygen, halides and trace metals; saturate olefins [3] | Convert heavy gas oil into lighter, saturated products [2] |
| Typical feeds | Naphtha, kerosene, diesel and gas oils [3] | Heavy gas oils from the crude and vacuum columns, the fluid catalytic cracker and the coker [2] |
| Typical conditions | About 290 to 430 °C (550 to 805 °F) and 7 to 180 bar (about 100 to 2,600 pounds per square inch) [5] | About 300 to 400 °C (570 to 750 °F) at 8 to 15 megapascals of hydrogen (about 1,160 to 2,180 pounds per square inch) [4] |
| Catalyst | Cobalt-molybdenum mainly for sulfur, nickel-molybdenum mainly for nitrogen [5] | Metals that add hydrogen, on an acidic silica-alumina or zeolite support that cracks [4] |
| Heat | Net heat release; reactor temperature typically rises 5 to 20 °F (3 to 11 °C) [3] | Cracking absorbs heat and saturation releases it; hydrogen is injected at several points to hold temperature [2] |
| Main products | Same stream with less sulfur and nitrogen | Jet fuel, diesel and gasoline components [2] |

Hydrotreating reactions are mostly kept below about 800 °F (427 °C) so that little cracking occurs, and they use roughly 200 to 800 standard cubic feet of hydrogen for each barrel processed [3]. Hydrocracking must saturate aromatic rings with hydrogen before it can break them, and the Penn State course describes it as a costly process [4].

## Why do refineries hydrotreat their streams?

- **To meet fuel specifications.** Hydrotreaters cut sulfur and nitrogen in finished products such as jet fuel and diesel [3].
- **To protect other catalysts.** Nitrogen and sulfur compounds deactivate catalysts, so hydrotreaters sit ahead of units such as the catalytic reformer and the cracking units [1][3].
- **To upgrade heavy, sulfur-rich oil.** A hydrocracker can turn high-sulfur material that would otherwise go to marine or boiler fuel into low-sulfur transport fuels [2].

The reactions convert sulfur to hydrogen sulfide, nitrogen to ammonia and oxygen to water, while metals stay behind on the catalyst [3][5].

## Where are hydroprocessing units in a refinery?

A large refinery may run five or more hydrotreaters [3]. The common ones are:

- **Naphtha hydrotreater:** cleans naphtha before the catalytic reformer. [3]
- **Kerosene or middle distillate hydrotreater:** treats kerosene for jet fuel. [3]
- **Gas oil or diesel hydrotreater:** treats diesel-range oil or pretreats vacuum gas oil going to a cracking unit. [3]

Hydrocrackers are less common; many refiners do not have one [2]. All these units need a steady hydrogen supply. Steam methane reforming is the main refinery source, because byproduct hydrogen from the catalytic reformer is generally not enough [9], and some refiners buy hydrogen, including from neighboring steam crackers [10].

## How does a hydrotreater work?

1. Liquid feed is mixed with hydrogen-rich gas [3][7].
2. The mixture is heated, first in feed/effluent heat exchangers by the hot reactor outlet stream and then in a fired heater [7][6].
3. It passes through a fixed-bed reactor, where the treating reactions take place [3][6].
4. The effluent is cooled, and a separator splits hydrogen-rich gas from liquid [3][6].
5. The gas is treated to remove hydrogen sulfide and recycled to the reactor; a stripper takes the light ends out of the liquid product [3].

In the naphtha hydrotreater that the US Chemical Safety and Hazard Investigation Board (CSB) investigated at Anacortes, naphtha was heated above 600 °F (316 °C) at more than 600 pounds per square inch gauge and mixed with hydrogen before the reactor [7]. Condensate is injected into the effluent to stop salts from forming in downstream equipment [5].

## Where integrity problems show up

| Unit / equipment | Typical integrity issue | In the Library |
|---|---|---|
| Feed/effluent heat exchangers, reactor circuit and other carbon steel in hot, high-pressure hydrogen | High temperature hydrogen attack (HTHA) | [High temperature hydrogen attack](/library/high-temperature-hydrogen-attack/), [Anacortes refinery explosion (2010)](/library/anacortes-refinery-explosion-2010/) |
| Cooler parts of hydrotreaters and reformer pretreater exchangers | Hydrochloric acid condensing; ammonium chloride corrosion and fouling | Hydrochloric acid corrosion, [Ammonium chloride corrosion](/library/ammonium-chloride-corrosion/) |
| Hydrocracker condensing areas | Corrosion by wet carbon dioxide | Carbon dioxide corrosion |
| Recycle gas amine scrubber and amine regenerator | Amine corrosion | Amine corrosion |

Sources: CSB, Anacortes investigation report (2014) [7] and HTHA safety alert (2016) [8]; Occupational Safety and Health Administration (OSHA) Technical Manual, Section IV, Chapter 2 (undated) [6].

HTHA forms fissures and cracks when carbon steel is held in hydrogen at high temperature and pressure; low carbon steels are most susceptible because their carbides react with hydrogen more readily than chromium and molybdenum carbides do [7]. At Anacortes in 2010, a carbon steel feed/effluent exchanger in the naphtha hydrotreater ruptured from HTHA, killing seven workers [7]. The industry predicts safe operating regions with the Nelson curves in American Petroleum Institute Recommended Practice 941 (API RP 941), *Steels for Hydrogen Service at Elevated Temperatures and Pressures in Petroleum Refineries and Petrochemical Plants*; the CSB found HTHA at Anacortes in conditions the carbon steel curve rated as safe, and noted that its microscopic, localized cracks are hard to find by inspection [8].

OSHA also notes that ammonium hydrosulfide, formed from the hydrogen sulfide and ammonia in the reactor effluent, can corrode equipment seriously below the water dew point [6].

## Sources

1. [Glossary: Catalytic hydrotreating, U.S. Energy Information Administration](https://www.eia.gov/tools/glossary/index.php?id=Catalytic+hydrotreating)
2. [Hydrocracking is an important source of diesel and jet fuel, U.S. Energy Information Administration, Today in Energy](https://www.eia.gov/todayinenergy/detail.php?id=9650), 2013-01-18
3. [Energy Bandwidth for Petroleum Refining Processes, U.S. Department of Energy, Industrial Technologies Program (prepared by Energetics Inc.)](https://www.energy.gov/sites/prod/files/2013/11/f4/bandwidth.pdf)
4. [FSC 432 Petroleum Refining, Lesson 7: Catalytic Conversion Processes Part 1, Penn State College of Earth and Mineral Sciences (S. Eser)](https://courses.ems.psu.edu/fsc432/book/export/html/527)
5. [An Overview of Hydrotreating, American Institute of Chemical Engineers, Chemical Engineering Progress](https://www.aiche.org/resources/publications/cep/2021/october/overview-hydrotreating)
6. [OSHA Technical Manual, Section IV, Chapter 2: Petroleum Refining Processes, Occupational Safety and Health Administration](https://www.osha.gov/otm/section-4-safety-hazards/chapter-2)
7. [Investigation Report: Catastrophic Rupture of Heat Exchanger, Tesoro Anacortes Refinery, Report No. 2010-08-I-WA, U.S. Chemical Safety and Hazard Investigation Board](https://www.csb.gov/assets/1/7/tesoro_anacortes_2014-may-01.pdf)
8. [Safety Alert: Preventing High Temperature Hydrogen Attack (HTHA), U.S. Chemical Safety and Hazard Investigation Board](https://csb.gov/assets/1/20/safety_alert_htha_final1.pdf?16371=)
9. [AP-42, Section 5.1: Petroleum Refining, U.S. Environmental Protection Agency](https://www.epa.gov/sites/default/files/2020-09/documents/5.1_petroleum_refining.pdf)
10. [The Future of Petrochemicals, International Energy Agency](https://www.iea.org/reports/the-future-of-petrochemicals), 2018-10-04

Published by Winda Beacon (https://beacon.winda.ai).