# What is an inspection data management system (IDMS)?

> An inspection data management system (IDMS) is the database where a plant keeps fixed equipment inspection records and the results calculated from them. It holds equipment data, monitoring locations, thickness readings and findings, and turns repeat readings into corrosion rates and remaining life. US process safety rules require the underlying inspection records.

- Label: Fact
- Type: Explainer
- Published: 2026-11-14T11:57:56+09:00
- By: Jun Zhong
- Researched and drafted by: Beacon's AI newsroom
- Checked by: Jun Zhong on 2026-11-14
- Topics: LNG, Pipelines, Refining
- Canonical: https://beacon.winda.ai/library/inspection-data-management-system/

## Why does it matter?

In 2002, an inspector at a refinery in Richmond, California, had extra readings taken beside a monitored elbow and found that a section of straight pipe had lost about a third of its wall [1]. Site rules sent such extra findings to a free-text history note instead of the database of permanent readings, and no new monitoring location was added, so the section was never inspected again [1]. It ruptured on August 6, 2012 [1]. The US Chemical Safety and Hazard Investigation Board (CSB) also recommended a formal technical review before anyone lowers the alert thickness stored in an inspection database [1].

## What does an IDMS hold?

Every record group in the table traces to a US rule, to the refinery checklist of the US Occupational Safety and Health Administration (OSHA), or to the CSB's Richmond findings, as the last column shows [3][4][5][1].

| Record group | Typical contents | Who asks for it |
|---|---|---|
| Equipment and design data | Materials of construction, design codes and standards, piping and instrument diagrams | Process safety information, 29 CFR 1910.119(d)(3) [3] |
| Equipment history | Installation date, specifications and strength, service class, repairs, replacements, operating changes | OSHA refinery inspection checklist [4] |
| Monitoring locations and readings | Each condition monitoring location (CML), the original thickness, and the place, date and result of every later reading | OSHA refinery inspection checklist [4]; CSB [1] |
| Limits | Retirement thickness; the alert thickness that triggers an engineering review | OSHA checklist [4]; CSB [1] |
| Inspection and test records | Date, inspector's name, equipment identifier, what was done, results | 29 CFR 1910.119(j)(4)(iv) [3] |
| Findings and recommendations | Findings, notes, recommended repairs or replacements | CSB [1] |
| Pipeline integrity data | Pipe attributes, pressure test history, coating and cathodic protection surveys, in-line inspection results, internal corrosion monitoring results | 49 CFR 192.917(b) [5] |

## What does an IDMS do with the data?

- **Calculates rates and remaining life.** The Richmond refinery's database stored findings, notes and wall thickness values, tracked corrosion rates, and used a minimum value entered by the inspector to project remaining life [1]. OSHA has cited refineries for not calculating corrosion rates to set inspection intervals, and for rates above the expected value that went unaddressed [2].
- **Triggers reviews.** Reaching an alert thickness started an engineering evaluation of the minimum required thickness [1].
- **Flags anomalies.** OSHA, citing industry process safety guidance, says inspection data should be reviewed for suspicious values and that employers should be able to analyze data efficiently and highlight anomalies; a reading that shows a wall getting thicker must be retested and resolved [2][4].
- **Supports decisions.** Database reports were used for remaining-life estimates, replacement recommendations and turnaround work scope [1].
- **Keeps the record.** Gas transmission and hazardous liquid pipeline operators must keep integrity management records for the useful life of the pipeline [5][6].

A maintenance management system is built around a different object. A Pacific Northwest National Laboratory guide for the DOE Federal Energy Management Program treats a computerized maintenance management system (CMMS) as software for running operations and maintenance work: raising, ranking and tracking work orders, scheduling preventive maintenance and keeping the spare parts inventory [8]. The inspection database in the CSB's Richmond account held readings and findings instead, and worked out rates and remaining life from them [1].

## What records do US rules require?

Under the US process safety management (PSM) standard, each inspection or test on covered process equipment must be documented with its date, the person who did it, the equipment identifier, a description and the results, and equipment deficiencies outside acceptable limits must be corrected [3]. Pipeline rules go further on data use: gas transmission operators must integrate a long list of attributes and survey results into their threat and risk assessment [5], and liquid operators must analyze all available information on the integrity of the whole pipeline [6]. See [What inspection records do codes require you to keep?](/library/inspection-record-requirements/).

## Where integrity problems show up

| What it finds well | What it can miss or get wrong | In the Library |
|---|---|---|
| Corrosion rate and remaining life at every recorded CML [1] | Damage written up as free text instead of CML data, which falls out of rate and remaining-life calculations (Richmond, 2012) [1] | [What are condition monitoring locations (CMLs)?](/library/condition-monitoring-locations/) |
| Equipment approaching its alert or retirement thickness [1][4] | An alert thickness lowered without a documented technical review, which the CSB recommended against [1] | [Minimum required thickness](/glossary/minimum-required-thickness/) |
| Readings that break the trend, when checks are built in [2] | Readings showing a wall growing thicker, left unresolved, as OSHA found in refinery inspections [2][4] | [Corrosion rate](/glossary/corrosion-rate/) |
| Components that carry monitoring locations [7] | Components with none: a Philadelphia refinery circuit had 141 CMLs in 2019 and none on the elbow that ruptured [7] | [What should an inspection plan contain?](/library/inspection-plan/) |
| Pipeline condition data integrated across the system [5] | Lessons from one segment not applied to similar ones; after the 2012 Sissonville, West Virginia, rupture, the National Transportation Safety Board (NTSB) recommended using integrity data from high consequence area lines on the rest of the system [9] | [What is pipeline integrity management?](/library/pipeline-integrity-management/) |

Sources: CSB final report on the 2012 Richmond refinery fire, 2015 [1]; CSB report No. 2019-04-I-PA, 2022 [7]; OSHA 3918, 2017 [2]; OSHA CPL 03-00-004, 2007 [4]; NTSB/PAR-14/01, 2014 [9].

## Sources

1. [Final Investigation Report: Chevron Richmond Refinery Pipe Rupture and Fire, US Chemical Safety and Hazard Investigation Board (CSB)](https://www.csb.gov/assets/1/17/Chevron_Final_Investigation_Report_2015-01-28.pdf?15397), 2015-01-28
2. [Process Safety Management for Petroleum Refineries: Lessons Learned from the Petroleum Refinery Process Safety Management National Emphasis Program (OSHA 3918), US Occupational Safety and Health Administration (OSHA)](https://www.osha.gov/Publications/OSHA3918.pdf)
3. [29 CFR 1910.119, Process safety management of highly hazardous chemicals, eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-H/section-1910.119)
4. [CPL 03-00-004, Petroleum Refinery Process Safety Management National Emphasis Program, US Occupational Safety and Health Administration (OSHA)](https://www.osha.gov/enforcement/directives/cpl-03-00-004)
5. [49 CFR Part 192, Subpart O, Gas Transmission Pipeline Integrity Management (sections 192.917 and 192.947), eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-49/part-192/subpart-O)
6. [49 CFR 195.452, Pipeline integrity management in high consequence areas, eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-49/section-195.452)
7. [Fire and Explosions at Philadelphia Energy Solutions Refinery Hydrofluoric Acid Alkylation Unit, Investigation Report No. 2019-04-I-PA, US Chemical Safety and Hazard Investigation Board (CSB)](https://www.csb.gov/assets/1/20/PES_Final_Report_Published_October_2022_r1.pdf?16845), 2022-10-11
8. [Operations & Maintenance Best Practices: A Guide to Achieving Operational Efficiency (G. P. Sullivan et al.), PNNL-13890, Pacific Northwest National Laboratory for the US Department of Energy, Federal Energy Management Program](https://www.pnnl.gov/main/publications/external/technical_reports/PNNL-13890.pdf)
9. [Pipeline Accident Report: Columbia Gas Transmission Corporation Pipeline Rupture, Sissonville, West Virginia, December 11, 2012 (NTSB/PAR-14/01), US National Transportation Safety Board (NTSB)](https://www.ntsb.gov/investigations/AccidentReports/Reports/PAR1401.pdf)

Published by Winda Beacon (https://beacon.winda.ai).