# What are robotic crawlers for inspection?

> Robotic crawlers are remotely controlled or automated vehicles that carry inspection sensors along or inside pipes, vessels and tanks. Examples include ultrasonic scanners on vessel shells, magnetic flux leakage scanners on tank floors and in-pipe robots for pipelines that cannot be pigged. They reach places people cannot easily reach and record data by position.

- Label: Fact
- Type: Explainer
- Published: 2026-11-13T15:24:40+09:00
- By: Jun Zhong
- Researched and drafted by: Beacon's AI newsroom
- Checked by: Jun Zhong on 2026-11-13
- Topics: Pipelines, Refining, Upstream and offshore
- Canonical: https://beacon.winda.ai/library/robotic-crawlers/

## Why does it matter?

Smart pigs are loaded and retrieved at points with a special arrangement of pipes and valves [7]. A natural gas line may have plug valves, mitered bends and no such stations: can it be inspected from inside while it stays in service? Research begun in 2001, and supported by the US Pipeline and Hazardous Materials Safety Administration (PHMSA) since 2004, produced two untethered, remotely controlled robots for such lines [1][2]. One carries a remote field eddy current (RFEC) sensor for 6- and 8-inch pipe and the other a magnetic flux leakage (MFL) sensor for 20- to 26-inch pipe [2]. The robots are designed to pass obstructions including plug valves [1], and the 2013 final report describes demonstrations in live pipelines with launch through a hot tap [2].

## What kinds of inspection crawlers are there?

| Type | Where it works | Sensors | In the Library |
|---|---|---|---|
| In-pipe robots for unpiggable gas lines | Live transmission and distribution lines, through plug valves, bends and hot taps [1][2] | RFEC or MFL, with video for driving [2] | How are unpiggable pipelines inspected? |
| Research robots for gas mains | Cast iron and steel distribution mains [4] | Normal-beam electromagnetic acoustic transducers (EMAT); guided wave EMAT under study [4] | [Guided wave testing](/glossary/guided-wave-testing/) |
| Internal riser and pipe tools | Liquid-filled risers, horizontal runs, bends and T-connections [5] | Ultrasonic corrosion mapping and time-of-flight diffraction for welds [5] | [Conventional UT vs phased array (PAUT) vs time-of-flight diffraction (TOFD)](/library/ut-vs-paut-vs-tofd/) |
| Tank floor and wall scanners | Storage tank floors and vertical walls [6] | MFL [6] | [Magnetic flux leakage](/glossary/magnetic-flux-leakage/) |

Sources: PHMSA R&D projects 353 and 723 [1][4]; PHMSA-hosted final report, 2013 [2]; MMS riser study, 2003 [5]; HSE COMAH technical measures document [6].

## How do crawlers move and record data?

**Power and range.** Untethered robots carry batteries, and battery capacity sets how far they can go. The 6- to 8-inch robot in the PHMSA-supported program listed a maximum range of 0.6 mile per launch site, speeds up to 4 in/s and a maximum operating pressure of 750 psig [2]. Early deployments used roughly 15% of battery capacity during set-up, launch and retrieval, so the program added a launch-assist module whose short tether powers the robot until it enters the pipe [2]. A later PHMSA project set out to generate power and thrust from the gas flow itself to extend range [3].

**Driving.** Operators steer in-pipe robots remotely, using front and rear video [2]. The internal riser tool described in a 2003 study for the US Minerals Management Service (MMS) is motor-driven and propels itself through vertical and horizontal sections of a liquid-filled riser with no flow [5].

**Recording.** HSE notes that large-area methods such as corrosion mapping and floor scanners usually present their results as computer plots, and that a polished plot neither shows a technique's limits nor proves it was applied correctly [6].

## What are their limits?

- **Range and conditions.** Battery-powered robots cover limited distances per launch and have pressure ratings [2][3].
- **Reach near obstructions.** HSE notes that MFL floor scanners cannot cover the floor right up to vertical obstructions and the shell, because the sensor sits between magnet poles [6].
- **Wall thickness.** MFL needs the steel near magnetic saturation, which limits the thickness it can inspect [6].
- **Surface and set-up.** Roughness, corrosion, debris on the magnets and jolts to the scanner degrade MFL results, and its high set-up effort makes it prone to human error [6].
- **Process conditions.** The internal riser tool needed the riser bled down and filled with liquid, with lost production as a result [5].

## Where integrity problems show up

| What it finds well | What it can miss or get wrong | In the Library |
|---|---|---|
| Metal loss in live, unpiggable gas lines, with RFEC or MFL on in-pipe robots [1][2] | Pipe beyond the robot's range from each launch site [2][3] | How are unpiggable pipelines inspected? |
| Metal loss on both faces of tank floors, with MFL scanners [6] | Floor next to the shell and obstructions; which face the loss is on; an accurate remaining wall [6] | [Magnetic flux leakage](/glossary/magnetic-flux-leakage/) |
| Riser corrosion and weld damage, from inside [5] | Inspection only after the riser is bled down and filled with liquid [5] | What is in-line inspection (ILI) and pigging? |

Sources: PHMSA R&D project 353 and final report [1][2]; PHMSA R&D project 728 [3]; MMS riser study, 2003 [5]; HSE COMAH technical measures document [6].

## Sources

1. [Completion of Development of Robotics Systems for Inspecting Unpiggable Transmission Pipelines (R&D project 353), US Pipeline and Hazardous Materials Safety Administration (PHMSA), Pipeline Safety Research and Development](https://primis.phmsa.dot.gov/rd/projects/353)
2. [Final Public Report on Project DTPH56-10-T-000008: Completion of Development of Robotics Systems for Inspecting Unpiggable Transmission Pipelines, NYSEARCH/Northeast Gas Association, hosted by PHMSA](https://primis.phmsa.dot.gov/rd/FileGet/7935/NYSEARCH-DoT-_robotics-final-report_-PUBLIC-022013.pdf), 2013-02-19
3. [On-Board Power and Thrust Generation for Robots for the Inspection of Unpiggable Natural Gas Pipelines (R&D project 728), US Pipeline and Hazardous Materials Safety Administration (PHMSA), Pipeline Safety Research and Development](https://primis.phmsa.dot.gov/rd/projects/728)
4. [EMAT Guided wave technology for inline inspections of unpiggable natural gas pipelines (R&D project 723), US Pipeline and Hazardous Materials Safety Administration (PHMSA), Pipeline Safety Research and Development](https://primis.phmsa.dot.gov/rd/projects/723)
5. [Evaluation of Methods for Detecting and Monitoring of Corrosion and Fatigue Damage in Risers (M. Lozev, B. Grimmett, E. Shell, R. Spencer), Technical Assessment Program project 433, US Minerals Management Service (now Bureau of Safety and Environmental Enforcement, BSEE)](https://www.bsee.gov/sites/bsee.gov/files/tap-technical-assessment-program//433aa.pdf), 2003-11-04
6. [Inspection/Non Destructive Testing (COMAH technical measures document), UK Health and Safety Executive (HSE)](https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm)
7. [Fact Sheet: In-Line Inspections (Smart Pig), US Pipeline and Hazardous Materials Safety Administration (PHMSA)](https://primis.phmsa.dot.gov/stakeholder-comms/factsheets/fssmartpig)
8. [29 CFR 1910.146, Permit-required confined spaces, eCFR, US Office of the Federal Register](https://www.ecfr.gov/current/title-29/section-1910.146)

Published by Winda Beacon (https://beacon.winda.ai).