Specified minimum yield strength (SMYS)
Specified minimum yield strength (SMYS) is the lowest yield strength that a steel pipe's manufacturing or purchase specification requires.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked
Also called SMYS
For gas pipelines, 49 CFR 192.3 takes it from a listed pipe specification, and for unknown or unlisted specifications 49 CFR 192.107 sets the value from tensile tests or a default of 24,000 pounds per square inch (165 megapascals) 1,2. Hazardous liquid rules (49 CFR 195.2) tie it to the purchase specification and also define stress level as hoop stress, normally stated as a percentage of SMYS 3.
It is the minimum strength the pipe steel is promised to have. Pipeline rules judge how hard a pipe is working by its stress as a percentage of that number 3,4.
See alsoDesign pressure
Sources
- 1.49 CFR 192.3, Definitions · eCFR, US Office of the Federal Register
- 2.49 CFR 192.107, Yield strength (S) for steel pipe · eCFR, US Office of the Federal Register
- 3.49 CFR 195.2, Definitions · eCFR, US Office of the Federal Register
- 4.49 CFR 192.611, Change in class location: Confirmation or revision of maximum allowable operating pressure · eCFR, US Office of the Federal Register
- 5.49 CFR 192.105, Design formula for steel pipe · eCFR, US Office of the Federal Register