Pipe-to-soil potential

·4 sources

Short answer

Pipe-to-soil potential is the voltage between a buried pipe and the soil around it, measured against a reference electrode placed in contact with the soil.

By , Editor·Researched and drafted by ·Checked by , Editor·Last checked

It is the main reading used to judge cathodic protection: one criterion for steel in Appendix D to 49 CFR Part 192 is at least 0.85 volt negative against a saturated copper-copper sulfate half cell, measured with protective current on and allowing for voltage drops other than across the pipe-soil boundary 2. Hazardous liquid pipelines use criteria from NACE SP0169, incorporated by reference (49 CFR 195.571) 4.

It is a voltmeter reading between the pipe and a reference probe on the ground, showing whether protective current reaches the pipe. On onshore gas transmission lines, a low annual test station reading requires the operator to find how far the weak protection extends, where needed by surveys at about 5-foot spacing (49 CFR 192.465(f)) 1,3.

Sources

  1. 1.TM 5-811-7, Electrical Design, Cathodic Protection (Technical Manual) · Headquarters, US Department of the Army (hosted by the Whole Building Design Guide) ·
  2. 2.Appendix D to Part 192, Criteria for Cathodic Protection and Determination of Measurements · eCFR, US Office of the Federal Register
  3. 3.49 CFR Part 192, Subpart I, Requirements for Corrosion Control (192.465 Monitoring and remediation) · eCFR, US Office of the Federal Register
  4. 4.49 CFR Part 195, Subpart H, Corrosion Control (195.553 special definitions; 195.571 criteria for cathodic protection) · eCFR, US Office of the Federal Register