Pipe-to-soil potential
Pipe-to-soil potential is the voltage between a buried pipe and the soil around it, measured against a reference electrode placed in contact with the soil.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked
It is the main reading used to judge cathodic protection: one criterion for steel in Appendix D to 49 CFR Part 192 is at least 0.85 volt negative against a saturated copper-copper sulfate half cell, measured with protective current on and allowing for voltage drops other than across the pipe-soil boundary 2. Hazardous liquid pipelines use criteria from NACE SP0169, incorporated by reference (49 CFR 195.571) 4.
It is a voltmeter reading between the pipe and a reference probe on the ground, showing whether protective current reaches the pipe. On onshore gas transmission lines, a low annual test station reading requires the operator to find how far the weak protection extends, where needed by surveys at about 5-foot spacing (49 CFR 192.465(f)) 1,3.