Short answer

Remaining life is the time left before damage takes a component to the limit at which it can no longer safely stay in service.

By , Editor·Researched and drafted by ·Checked by , Editor·Last checked

For wall thinning, the US Chemical Safety Board (CSB) describes it as the time before piping becomes too thin and must be replaced, projected from thickness readings, a minimum thickness and tracked corrosion rates 1. For cracks, US gas transmission rules define it as the time a crack needs to reach a size that would fail at the maximum allowable operating pressure, and require a fresh evaluation before half of it has passed (49 CFR 192.712) 2.

It is a countdown from today's wall, or today's crack, to the limit. Inspection timing is often tied to it: some US gas pipeline reassessment intervals are half the time the largest remaining defect needs to grow to a critical size (49 CFR 192.939) 3.

Sources

  1. 1.Final Investigation Report: Chevron Richmond Refinery Pipe Rupture and Fire (Report No. 2012-03-I-CA) · US Chemical Safety and Hazard Investigation Board (CSB)
  2. 2.49 CFR 192.712, Analysis of predicted failure pressure and critical strain level · eCFR, US Office of the Federal Register