What is leak detection and repair (LDAR) for methane?
Leak detection and repair (LDAR) is a work practice: a facility lists components that can leak, checks them on a schedule and repairs leaks by deadlines. Checks use EPA Method 21 analyzers, optical gas imaging cameras or sensory inspections. For US oil and gas methane, the federal rules are 40 CFR part 60, subparts OOOOb and OOOOc.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked ·Next review
What does an LDAR program include?
The US Environmental Protection Agency (EPA) describes LDAR as a routine of finding leaking equipment and fixing it within a set time, so that emissions fall 1. A working program has five parts.
| Element | What it involves |
|---|---|
| Component inventory | Every regulated valve, connector, pump and other component gets a unique ID, and its location is checked against drawings |
| Leak definition | The instrument reading, in parts per million (ppm), that counts as a leak under the applicable rule |
| Monitoring | Checks at fixed intervals, from weekly to yearly; connectors may run on cycles of 2, 4 or 8 years |
| Repair | A first repair attempt within 5 days and a final repair within 15 days; parts that need a shutdown can go on a delay-of-repair list |
| Records | Component lists, readings, repair attempts and delay-of-repair entries, kept for audits |
Source: EPA, Leak Detection and Repair: A Best Practices Guide (2007) 1.
Which components leak?
Method 21 applies to valves, flanges and other connections, pumps, compressors, pressure relief devices, process drains, open-ended lines and certain vents and seals 2. Earlier EPA studies estimated that valves and connectors, the most numerous components, account for more than 90% of emissions from leaking equipment 1. The integrity table below shows where each type tends to leak.
How are leaks detected?
| Method | How it works | What it tells you |
|---|---|---|
| EPA Method 21 | A portable analyzer's probe is traced around each seal or joint | A concentration reading compared with the rule's leak threshold, not a mass emission rate |
| Optical gas imaging (OGI) | An infrared camera makes VOC and methane plumes visible | Where a leak is |
| Audible, visual and olfactory (AVO) inspection | Operators listen, look and smell during site visits | Obvious leaks |
| EPA-approved alternative methods | Aerial, fixed-sensor and other screening technologies approved under 40 CFR 60.5398b(d) | Whether a site has emissions above the method's detection level |
Sources: EPA Method 21 (2017) 2; EPA OGI fact sheet (2023) 3; EPA fugitive emissions FAQ (updated August 2026) 4; EPA alternative test methods page (updated 22 October 2026) 5.
EPA's protocol for OGI, Appendix K to 40 CFR part 60, sets camera performance, operator training and conditions such as wind, temperature contrast and viewing distance under which a survey counts; its survey requirements apply at natural gas processing plants 3. For alternative methods, EPA's list showed 19 approved methods as of its page update of 22 October 2026, mostly for periodic screening 5.
What is the US regulatory basis for methane LDAR?
LDAR requirements also apply under Clean Air Act rules for volatile organic compounds (VOCs) and hazardous air pollutants, for example at refineries and chemical plants 1. In those programs, most New Source Performance Standards (NSPS) define a leak as 10,000 ppm, while many hazardous air pollutant standards use 500 or 1,000 ppm 1.
For oil and gas methane, EPA published a final rule on 8 March 2024 (89 FR 16820), effective 7 May 2024 6. Subpart OOOOb sets methane and VOC standards for new, modified and reconstructed sources; subpart OOOOc sets emissions guidelines for existing sources, which states put into effect through their own plans 6. Under OOOOb, fugitive emissions monitoring covers well sites, centralized production facilities and compressor stations built, modified or reconstructed after 6 December 2022, using AVO inspections (at all site types except those on the Alaska North Slope) and, depending on the site type, OGI or Method 21 4. A fugitive emission is any AVO indication, any emission an OGI camera shows, or a Method 21 reading of 500 ppm by volume or more, and each one must be repaired 4.
The rule's status has changed several times; as of 25 October 2026, epa.gov and the Federal Register record these actions 8,6,7:
| Date | EPA action |
|---|---|
| 12 March 2025 | EPA announces a broad reconsideration of OOOOb and OOOOc 8 |
| 31 July 2025 | Interim final rule extends certain OOOOb deadlines and the OOOOc state plan deadline 6 |
| 3 December 2025 | Final rule (90 FR 55671) confirms the extensions: several OOOOb items, including repair rules for low-emission valves and packing and the Super Emitter Program, move to 22 January 2027; OOOOc state plans are due 22 January 2027 7 |
| 4 April 2026 | Final rule revises two narrow items: temporary flaring of associated gas, and heat-value monitoring for flares and enclosed combustion devices; EPA says further amendments are in development 8 |
The December 2025 rule moved dates; it did not reopen the 2024 rule's substantive requirements 7.
Where integrity problems show up
| Component | Where it leaks and why | In the Library |
|---|---|---|
| Valves | At the stem or gland, usually from packing or O-ring failure caused by normal wear or poor maintenance | What is mechanical integrity (MI)? |
| Flanges and other connectors | Gasket failure and bolts that were not torqued correctly | What is mechanical integrity (MI)? |
| Pumps and compressors | Mainly at the seals | What is mechanical integrity (MI)? |
| Pressure relief devices | Relief valves leak at the seat when poorly seated, run close to set pressure or have a worn or damaged seal; rupture disks leak at the gasket if badly installed | What does a pressure relief valve do? |
Sources: EPA, LDAR Best Practices Guide (2007) 1; 29 CFR 1910.119(j)(1), which lists piping components such as valves, relief and vent systems, and pumps among the equipment covered by mechanical integrity (eCFR, as of 22 October 2026) 9.
Common questions
- Does LDAR measure how much methane is leaking?
- Not directly. Method 21 locates and classifies leaks against a threshold but does not measure a mass emission rate, and OGI shows where a leak is. Many approved alternative methods are rated by the smallest leak they can detect, in kilograms per hour.
- Is LDAR the same as mechanical integrity?
- No. LDAR is an air emissions work practice under EPA rules. Mechanical integrity is part of the Occupational Safety and Health Administration (OSHA) process safety management standard, 29 CFR 1910.119(j). It covers equipment such as vessels, piping and valves, relief systems and pumps, and requires deficiencies outside acceptable limits to be fixed before the equipment is used again, or promptly while other measures keep it operating safely. The two programs often deal with the same valves, pumps and relief devices.
Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.
Sources
- 1.Leak Detection and Repair: A Best Practices Guide · US Environmental Protection Agency (EPA)
- 2.Method 21: Determination of Volatile Organic Compound Leaks · US Environmental Protection Agency (EPA)
- 3.Technical fact sheet: Using optical gas imaging in leak detection (Appendix K) · US Environmental Protection Agency (EPA) ·
- 4.Frequently Asked Questions: Fugitive Emissions · US Environmental Protection Agency (EPA)
- 5.Oil and Gas Alternative Test Methods · US Environmental Protection Agency (EPA), Air Emission Measurement Center
- 6.Extension of Deadlines in Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review Final Rule (interim final rule), FR Doc. 2025-14531 · Federal Register (EPA) ·
- 7.Oil and Natural Gas Sector Climate Review: Extension of Deadlines in Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources (final rule), 90 FR 55671, FR Doc. 2025-21788 · Federal Register (EPA) ·
- 8.2026 Final Rule to Reduce Burden on the Oil and Natural Gas Industry · US Environmental Protection Agency (EPA)
- 9.29 CFR 1910.119, Process safety management of highly hazardous chemicals · Electronic Code of Federal Regulations (eCFR)