What is linear polarization resistance (LPR) monitoring?
Linear polarization resistance (LPR) monitoring estimates a metal's instantaneous corrosion rate by nudging its potential and measuring the current. The ratio of potential shift to current is the polarization resistance, which is inversely related to the corrosion rate. ASTM G59 describes the measurement and ASTM G96 its use for online monitoring.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked ·Next review
Why does it matter?
An LPR reading is not a direct measurement of metal loss. The instrument converts an electrical ratio into a rate with constants that depend on the metal and its environment, and ASTM's guide to online corrosion monitoring says the method may need calibration against other techniques to give true corrosion rates 2. The same guide places its main value in detecting a change in corrosion rate within minutes, which can point to an unwanted change in the process 2. It also works only while a conductive liquid wets the electrodes 3,5.
How does LPR work?
An LPR probe carries two or three electrodes, usually all of the same metal, that sit in the process fluid 3. The measurement then runs in four steps.
- Find the resting potential. A corroding metal settles at its corrosion potential, where no net current flows 1,4.
- Nudge it. The instrument shifts the potential a little away from that value, by less than about 30 millivolts (mV) according to a 2020 review 4. A US Federal Highway Administration (FHWA) procedure for steel in concrete, for example, steps the potential by 4, 8 and 12 mV and finishes within about 2 minutes 6.
- Measure the slope. In that narrow window, current changes almost in proportion to potential. The slope of potential against current at zero current is the polarization resistance (Rp) 1,4.
- Convert to a rate. A relationship published by Stern and Geary in 1957 links Rp to the corrosion current through a constant, B, set by the anodic and cathodic Tafel slopes of the metal in that environment. Faraday's law then turns current into metal loss per year 1,4.
corrosion current density = B ÷ Rp
B = Stern-Geary constant (from the anodic and cathodic Tafel slopes)
Rp = polarization resistance (potential shift ÷ current, near the corrosion potential)
Each step carries an assumption: that the probe metal behaves like the equipment wall, that B is known for that metal and fluid, and that corrosion is spread fairly evenly over the electrode 1,2,4.
Where is LPR used?
- Online monitoring in plant equipment. ASTM G96 covers polarization resistance as a way to read instantaneous corrosion rates, intermittently or continuously, without removing the probe 2.
- Process upsets and inhibitor control. The guide notes early warning of corrosive conditions before significant damage occurs, and a rising rate as a signal that more inhibitor is needed 2.
- Laboratory screening. ASTM G59 lists ranking alloys and inhibitors by resistance to general corrosion; the UK Institute of Corrosion (ICorr) reports that LPR is common in lab testing of treatment chemicals, since lab conditions suit the method better than many sites in the field do 1,5.
- Other industries. The FHWA uses LPR to estimate the rate of rebar corrosion in concrete bridge members 6.
A 2019 review by researchers at the US National Energy Technology Laboratory (NETL) calls LPR the most commercialized electrochemical corrosion sensor, because operation and interpretation are relatively simple 3.
What are the limits of LPR?
- It needs an electrolyte. Electrochemical sensors generally need an ion-conducting liquid such as water and do not suit non-conductive environments without special designs 3. ICorr notes that for this reason LPR can be of limited value offshore 5.
- It reports general corrosion. Polarization resistance relates to general corrosion near the corrosion potential 1, and the estimate averages over the electrode surface, so visual examination of the electrode is needed to judge how uneven the attack was 2. The 2020 review describes electrochemical noise as better suited to localized corrosion 4.
- Its constants and biases. B must be known or estimated 4; solution resistance and electrode capacitance can bias the measured Rp 1; and the imposed signal can push the corrosion rate away from its true value if the settings are poorly chosen 3.
- It is a snapshot. The FHWA notes that the instantaneous rate fluctuates over time, and that using it to predict remaining service life is limited and still debated 6.
Where integrity problems show up
| What it finds well | What it can miss or get wrong | In the Library |
|---|---|---|
| A quick change in general corrosion rate after a process upset or a change in inhibitor dosing 2,5 | Pits and other local attack: Rp relates to general corrosion, averaged over the electrode 1,2 | What is pitting corrosion?, How do corrosion inhibitors work? |
| Rates where a conductive water phase keeps the electrodes wetted 3 | Gas, dry hydrocarbon or other non-conductive phases, where electrical resistance probes still work 3,5 | Electrical resistance probe |
| Ranking of alloys and inhibitors under controlled conditions 1 | Absolute rates when B is assumed or the measurement is biased by solution resistance or capacitance 1,4; true rates may need calibration 2 | Corrosion rate |
| The rate at the moment of measurement 6 | The long-term average: instantaneous values fluctuate 6 | Long-term corrosion rate |
Sources: ASTM G59 1 and G96 2 public scope pages; Wright et al., NETL review, 2019 3; Khan et al., 2020 4; ICorr, 2014 5; FHWA 6.
Common questions
- What is the difference between LPR and an ER probe?
- An electrical resistance (ER) probe tracks the cumulative metal loss of its element, and a rate is inferred over time; LPR gives an instantaneous rate within minutes. ER probes also work in non-conductive fluids, where LPR does not. See [Corrosion coupons vs electrical resistance (ER) probes](/library/corrosion-coupons-vs-er-probes/).
- Can LPR detect pitting?
- Not reliably on its own. Polarization resistance relates to general corrosion, and electrochemical noise is the technique the 2020 review names for localized attack.
- How does LPR relate to electrochemical impedance spectroscopy (EIS)?
- EIS also yields a polarization resistance, but the 2020 review notes it is slower, because it needs low-frequency data, and harder to interpret than LPR.
Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.
Sources
- 1.ASTM G59, Standard Test Method for Conducting Potentiodynamic Polarization Resistance Measurements (product page, Scope and Significance and Use) (G59-97(2020) shown; edition not relied on) · ASTM International
- 2.ASTM G96, Standard Guide for Online Monitoring of Corrosion in Plant Equipment (Electrical and Electrochemical Methods) (product page, Scope and Significance and Use) (G96-90(2018) shown; edition not relied on) · ASTM International
- 3.Corrosion Sensors for Structural Health Monitoring of Oil and Natural Gas Infrastructure: A Review (R. F. Wright et al.), Sensors 19(18):3964 · MDPI, via PubMed Central (authors at the US National Energy Technology Laboratory) ·
- 4.Frontiers and Challenges in Electrochemical Corrosion Monitoring; Surface and Downhole Applications (A. Khan et al.), Sensors 20(22):6583 · MDPI, via PubMed Central ·
- 5.Corrosion Monitoring & Data Trending (2014 Corrosion Awareness Day presentation) · Institute of Corrosion (ICorr), UK ·
- 6.Bridge: Linear Polarization (LPR) (FHWA InfoTechnology) · US Federal Highway Administration (FHWA)