What are robotic crawlers for inspection?

·8 sources

Short answer

Robotic crawlers are remotely controlled or automated vehicles that carry inspection sensors along or inside pipes, vessels and tanks. Examples include ultrasonic scanners on vessel shells, magnetic flux leakage scanners on tank floors and in-pipe robots for pipelines that cannot be pigged. They reach places people cannot easily reach and record data by position.

By , Editor·Researched and drafted by ·Checked by , Editor·Last checked ·Next review

Why does it matter?

Smart pigs are loaded and retrieved at points with a special arrangement of pipes and valves 7. A natural gas line may have plug valves, mitered bends and no such stations: can it be inspected from inside while it stays in service? Research begun in 2001, and supported by the US Pipeline and Hazardous Materials Safety Administration (PHMSA) since 2004, produced two untethered, remotely controlled robots for such lines 1,2. One carries a remote field eddy current (RFEC) sensor for 6- and 8-inch pipe and the other a magnetic flux leakage (MFL) sensor for 20- to 26-inch pipe 2. The robots are designed to pass obstructions including plug valves 1, and the 2013 final report describes demonstrations in live pipelines with launch through a hot tap 2.

What kinds of inspection crawlers are there?

TypeWhere it worksSensorsIn the Library
In-pipe robots for unpiggable gas linesLive transmission and distribution lines, through plug valves, bends and hot taps 1,2RFEC or MFL, with video for driving 2How are unpiggable pipelines inspected?
Research robots for gas mainsCast iron and steel distribution mains 4Normal-beam electromagnetic acoustic transducers (EMAT); guided wave EMAT under study 4Guided wave testing
Internal riser and pipe toolsLiquid-filled risers, horizontal runs, bends and T-connections 5Ultrasonic corrosion mapping and time-of-flight diffraction for welds 5Conventional UT vs phased array (PAUT) vs time-of-flight diffraction (TOFD)
Tank floor and wall scannersStorage tank floors and vertical walls 6MFL 6Magnetic flux leakage

Sources: PHMSA R&D projects 353 and 723 1,4; PHMSA-hosted final report, 2013 2; MMS riser study, 2003 5; HSE COMAH technical measures document 6.

How do crawlers move and record data?

Power and range. Untethered robots carry batteries, and battery capacity sets how far they can go. The 6- to 8-inch robot in the PHMSA-supported program listed a maximum range of 0.6 mile per launch site, speeds up to 4 in/s and a maximum operating pressure of 750 psig 2. Early deployments used roughly 15% of battery capacity during set-up, launch and retrieval, so the program added a launch-assist module whose short tether powers the robot until it enters the pipe 2. A later PHMSA project set out to generate power and thrust from the gas flow itself to extend range 3.

Driving. Operators steer in-pipe robots remotely, using front and rear video 2. The internal riser tool described in a 2003 study for the US Minerals Management Service (MMS) is motor-driven and propels itself through vertical and horizontal sections of a liquid-filled riser with no flow 5.

Recording. HSE notes that large-area methods such as corrosion mapping and floor scanners usually present their results as computer plots, and that a polished plot neither shows a technique's limits nor proves it was applied correctly 6.

What are their limits?

  • Range and conditions. Battery-powered robots cover limited distances per launch and have pressure ratings 2,3.
  • Reach near obstructions. HSE notes that MFL floor scanners cannot cover the floor right up to vertical obstructions and the shell, because the sensor sits between magnet poles 6.
  • Wall thickness. MFL needs the steel near magnetic saturation, which limits the thickness it can inspect 6.
  • Surface and set-up. Roughness, corrosion, debris on the magnets and jolts to the scanner degrade MFL results, and its high set-up effort makes it prone to human error 6.
  • Process conditions. The internal riser tool needed the riser bled down and filled with liquid, with lost production as a result 5.

Where integrity problems show up

What it finds wellWhat it can miss or get wrongIn the Library
Metal loss in live, unpiggable gas lines, with RFEC or MFL on in-pipe robots 1,2Pipe beyond the robot's range from each launch site 2,3How are unpiggable pipelines inspected?
Metal loss on both faces of tank floors, with MFL scanners 6Floor next to the shell and obstructions; which face the loss is on; an accurate remaining wall 6Magnetic flux leakage
Riser corrosion and weld damage, from inside 5Inspection only after the riser is bled down and filled with liquid 5What is in-line inspection (ILI) and pigging?

Sources: PHMSA R&D project 353 and final report 1,2; PHMSA R&D project 728 3; MMS riser study, 2003 5; HSE COMAH technical measures document 6.

Common questions

Is a crawler the same as a smart pig?
No. A smart pig travels with the product flow and needs special pipe and valve arrangements to load and remove it. The robots described here drive themselves and are steered by an operator.
Do crawlers remove the need to enter tanks and vessels?
For some work. The in-pipe robots described here inspect gas lines from inside while the lines stay in service. When people do enter tanks or vessels, US rules on permit-required confined spaces, 29 CFR 1910.146, apply.
How are crawlers different from inspection drones?
Drones mostly fly cameras near surfaces, while crawlers hold sensors on or inside the equipment to measure it.

Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.

Sources

  1. 1.Completion of Development of Robotics Systems for Inspecting Unpiggable Transmission Pipelines (R&D project 353) · US Pipeline and Hazardous Materials Safety Administration (PHMSA), Pipeline Safety Research and Development
  2. 2.Final Public Report on Project DTPH56-10-T-000008: Completion of Development of Robotics Systems for Inspecting Unpiggable Transmission Pipelines · NYSEARCH/Northeast Gas Association, hosted by PHMSA ·
  3. 3.On-Board Power and Thrust Generation for Robots for the Inspection of Unpiggable Natural Gas Pipelines (R&D project 728) · US Pipeline and Hazardous Materials Safety Administration (PHMSA), Pipeline Safety Research and Development
  4. 4.EMAT Guided wave technology for inline inspections of unpiggable natural gas pipelines (R&D project 723) · US Pipeline and Hazardous Materials Safety Administration (PHMSA), Pipeline Safety Research and Development
  5. 5.Evaluation of Methods for Detecting and Monitoring of Corrosion and Fatigue Damage in Risers (M. Lozev, B. Grimmett, E. Shell, R. Spencer), Technical Assessment Program project 433 · US Minerals Management Service (now Bureau of Safety and Environmental Enforcement, BSEE) ·
  6. 6.Inspection/Non Destructive Testing (COMAH technical measures document) · UK Health and Safety Executive (HSE)
  7. 7.Fact Sheet: In-Line Inspections (Smart Pig) · US Pipeline and Hazardous Materials Safety Administration (PHMSA)
  8. 8.29 CFR 1910.146, Permit-required confined spaces · eCFR, US Office of the Federal Register