What inspection records do codes require you to keep?
Codes and regulations require inspection records showing what was inspected, when, by whom, how and with what result, and set how long they are kept. In the US, 29 CFR 1910.119(j)(4)(iv) sets that content for process plant equipment, while 49 CFR 192 and 195 set pipeline records, many kept for the pipeline's life.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked ·Next review
Why does it matter?
A folder of inspection reports is not the whole record the rules expect. Under the US gas transmission integrity management rules, operators must keep, for the pipeline's useful life, the documents behind every identification, calculation, justification, deviation and decision in the program, ready for review during an inspection 7. Records also carry the numbers that integrity decisions rest on: a corrosion rate is metal loss over time, so it needs dated readings from the same location (see Corrosion rate). In its refinery inspections, the US Occupational Safety and Health Administration (OSHA) cited inadequately recorded piping inspections and rising thickness readings that nobody investigated 16.
What must an inspection record contain?
| Record | Content the rule names | Rule |
|---|---|---|
| Process equipment inspection or test | Date; who performed it; serial number or other equipment identifier; what was done; results | 29 CFR 1910.119(j)(4)(iv) 1; 40 CFR 68.73(d)(4) 2 |
| Gas pipeline strength test | Operator, responsible employee and test company; test medium, pressure and duration; pressure charts or readings; significant elevation changes; leaks and failures and how they were handled | 49 CFR 192.517(a) 5 |
| Liquid pipeline pressure test | Charts and instrument calibration data; names; date and time; minimum test pressure; medium; facility and apparatus; any pressure discontinuities explained; an elevation profile where differences exceed 100 ft (30 m); temperature | 49 CFR 195.310(b) 9 |
| Alberta pipeline pressure test | A legible chart that runs unbroken through the whole test and shows when it began and ended (date and time), an unbroken record of pipe temperature, the location, and licence and segment numbers | Pipeline Rules, AR 125/2023, s. 36 14 |
| Corrosion control test or survey | Enough detail to show that protection is adequate or that no corrosive condition exists | 49 CFR 192.491(c) 4; 195.589(c) 11 |
| Pipe repair | Date, location and description | 49 CFR 192.709(a) 6; 195.404(c)(1) 10 |
How long must inspection records be kept?
| Rule | Record | Minimum retention |
|---|---|---|
| 29 CFR 1910.119(j)(4)(iv) and (o)(5) | Equipment inspections and tests; compliance audit reports | No period stated for inspections; the two most recent audit reports 1 |
| 40 CFR 68.200 | Records supporting an EPA risk management program | 5 years, unless subpart D says otherwise 3 |
| 49 CFR 192.709 | Gas transmission pipe repairs; other repairs; patrols, surveys, inspections and tests | Life of the pipe; 5 years; 5 years or until the next one, whichever is longer 6 |
| 49 CFR 192.517(a) and 192.947 | Strength tests; integrity management records | Useful life of the pipeline 5,7 |
| 49 CFR 192.491 and 195.589 | Corrosion control tests, surveys and inspections | At least 5 years, some for as long as the line is in service 4,11 |
| 49 CFR 195.404(c) | Liquid pipe repairs; other repairs; inspections and tests | Life of the pipe; 1 year; 2 years or until the next one, whichever is longer 10 |
| 49 CFR 195.266 and 195.310 | Construction records; the latest pressure test | Life of the facility; while the facility is in use 8,9 |
| Canada, SOR/99-294 s. 56 | Audit and inspection records; construction records, mill certificates, surveillance reports, defect documents | Longer of 5 years or two audit cycles; until at least 2 years after abandonment 12 |
| Alberta, AR 125/2023 s. 12 and 13 | Design-to-decommissioning records | As CSA Z662 requires, and passed to any buyer 14 |
| UK, Pressure Systems Safety Regulations 2000, reg. 14 | Latest examination report, and earlier ones that help judge safety or repairs | Kept at the site and handed to any new owner or user 15 |
Sources: the rule cited in each row, all checked 25 October 2026 1,6,10,12,14,15.
What do inspection codes add?
Under the US process safety rule, the inspection codes an employer adopts, such as API 510 or API 570, serve as its RAGAGEP (recognized and generally accepted good engineering practice) 16. OSHA presumes a violation when an employer departs from a "shall" statement in the RAGAGEP it adopted 17, so mandatory record provisions in those codes carry weight in an inspection. In Canada, the federal regulations apply their own retention periods in addition to those in the CSA standards they adopt 12.
How do records feed integrity decisions?
The Canada Energy Regulator's guidance lists what pipeline integrity records should hold: original pipe data (material, maker, grade, seam and girth weld type, welder identification, non-destructive examination, heat numbers, weld maps), coatings, pressure tests, maximum operating pressure, in-line inspection data, cathodic protection surveys, and inspections of relief valves, emergency shutdown devices and other valves 13. OSHA's refinery guidance adds that an irregular result must be retested rather than ignored, and the cause resolved 16. Records also follow the asset: in Alberta, a buyer missing records must prove fitness for service by engineering assessment 14, and in the UK the previous owner must hand records over in writing 15.
Where integrity problems show up
| Requirement | What it means for integrity records or work | In the Library |
|---|---|---|
| 1910.119(j)(4)(iv), five items per record | Each reading tied to an equipment identifier and date lets later readings at the same point give a rate 1 | What is mechanical integrity (MI)? |
| 192.947(d), decision and deviation documents | In a Canadian case at Prince George, British Columbia, in 2018, the TSB found no record of the rationale or approval for deferring a crack inspection before a rupture 7,18 | What is pipeline integrity management? |
| 192.709(c) and 195.404(c)(3), keep until the next inspection | The last record is the baseline for the next interval 6,10 | How are inspection intervals set for vessels, piping and tanks? |
| SOR/99-294 s. 56(g), mill certificates | Material records must outlast the pipeline by at least 2 years after abandonment 12 | What is a mill test certificate (EN 10204 3.1 and 3.2)? |
| AR 125/2023 s. 13, records on transfer | Lost or incomplete records shift the burden to an engineering assessment 14 | What does a technical due diligence check in an asset acquisition? |
| OSHA refinery findings on anomalous data | Increasing thickness readings went uninvestigated; data must be checked as it is recorded 16 | What is an inspection data management system (IDMS)? |
Sources: eCFR 1,6,7,10; SOR/99-294 12; AR 125/2023 14; OSHA 3918, 2017 16; TSB report P18H0088, 2020 18.
Common questions
- Does the PSM standard say how long to keep inspection records?
- Its paragraph on inspection documentation sets content but no period. EPA's Risk Management Program rule keeps supporting records for 5 years unless its subpart D says otherwise. See What is process safety management (PSM)?
- Is an inspection record the same as an inspection report?
- No. A report is one record; the rules also call for supporting documents, such as the decision and deviation records required for US gas integrity programs.
- Can inspection records be electronic?
- Yes, under conditions. Alberta accepts electronic pressure-test charts if a permanent copy stays accessible to the regulator and the sampling rate, resolution and range are adequate; the UK rules allow records kept in a form that can be reproduced at the site.
Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.
Sources
- 1.29 CFR 1910.119, Process safety management of highly hazardous chemicals · eCFR, US Office of the Federal Register
- 2.40 CFR 68.73, Mechanical integrity · eCFR, US Office of the Federal Register
- 3.40 CFR 68.200, Recordkeeping · eCFR, US Office of the Federal Register
- 4.49 CFR 192.491, Corrosion control records · eCFR, US Office of the Federal Register
- 5.49 CFR 192.517, Records (strength testing) · eCFR, US Office of the Federal Register
- 6.49 CFR 192.709, Transmission lines: Record keeping · eCFR, US Office of the Federal Register
- 7.49 CFR 192.947, What records must an operator keep? · eCFR, US Office of the Federal Register
- 8.49 CFR 195.266, Construction records · eCFR, US Office of the Federal Register
- 9.49 CFR 195.310, Records (pressure testing) · eCFR, US Office of the Federal Register
- 10.49 CFR 195.404, Maps and records · eCFR, US Office of the Federal Register
- 11.49 CFR 195.589, What corrosion control information do I have to maintain? · eCFR, US Office of the Federal Register
- 12.Canadian Energy Regulator Onshore Pipeline Regulations (SOR/99-294) · Justice Laws Website, Government of Canada
- 13.Guidance Notes for the Canadian Energy Regulator Onshore Pipeline Regulations · Canada Energy Regulator (CER)
- 14.Pipeline Rules, Alberta Regulation 125/2023 (office consolidation, with amendments up to AR 8/2026) · Alberta King's Printer
- 15.The Pressure Systems Safety Regulations 2000 (SI 2000/128), regulation 14, Keeping of records · legislation.gov.uk, The National Archives (Open Government Licence)
- 16.Process Safety Management for Petroleum Refineries: Lessons Learned from the Petroleum Refinery Process Safety Management National Emphasis Program (OSHA 3918-08) · US Occupational Safety and Health Administration (OSHA)
- 17.RAGAGEP in Process Safety Management Enforcement (memorandum to regional administrators) · US Occupational Safety and Health Administration (OSHA) ·
- 18.Pipeline Transportation Safety Investigation Report P18H0088: Pipeline rupture and fire, Westcoast Energy Inc., Prince George, British Columbia · Transportation Safety Board of Canada (TSB)