Skip to content
Beaconby Winda
FactAsset Integrity Management · IOWs and corrosion loops

Critical limit (integrity operating window)

·2 sources

Short answer

A critical limit is the tier of integrity operating window (IOW) limit beyond which corrosion can be rapid, so these limits are often alarmed.

By , Editor·Researched and drafted by ·Checked by , Editor·Last checked

API Recommended Practice 584 sorts IOW limits into three tiers: critical limits; standard limits, where damage builds slowly enough to plan a response; and informational limits, which are only trended 1. A common example is a low-pH limit for a crude distillation tower overhead 1.

It is the red line on a process variable that matters for equipment life. Responses are planned in advance, such as checking and raising neutralizer injection when overhead pH falls 1. Under the US process safety management standard, operating procedures must cover operating limits, the consequences of deviation and the steps to correct or avoid it (29 CFR 1910.119(f)) 2.

See alsoInjection point

Sources

  1. 1.Prevent Corrosion and Ensure Reliability (J. Danis), Chemical Engineering Progress · American Institute of Chemical Engineers (AIChE)
  2. 2.29 CFR 1910.119, Process safety management of highly hazardous chemicals · eCFR, US Office of the Federal Register