How are carbon dioxide pipelines different from natural gas pipelines?
Carbon dioxide (CO2) pipelines carry dense, high-pressure CO2 under the US hazardous liquid rules (49 CFR 195), not the gas pipeline rules. A release does not burn, but CO2 is an asphyxiant, heavier than air, that can collect in low ground. Wet CO2 corrodes carbon steel, and design must limit running fractures.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked ·Next review
Why does it matter?
On 22 February 2020, a 24-inch CO2 pipeline ruptured near Satartia, Mississippi, after soil movement on a rain-soaked hillside overloaded a girth weld 1. About 200 people were evacuated and 45 sought medical attention at local hospitals 1. The Pipeline and Hazardous Materials Safety Administration (PHMSA) found that the operator's dispersion model had left the village outside the affected radius, so the segment was not treated as one that could affect a high consequence area and the village was outside the operator's public awareness program 1.
How do CO2 and natural gas pipelines compare?
| CO2 pipeline | Natural gas transmission pipeline | |
|---|---|---|
| US federal rules | 49 CFR 195, shared with hazardous liquids 3 | 49 CFR 192 9 |
| What the rule defines | A fluid of more than 90% CO2 molecules compressed to a supercritical state 3 | Natural gas, flammable gas, or toxic or corrosive gas 9 |
| State and pressure in the pipe | Dense (supercritical) phase, about 1,200 to 2,700 psi 6 | Gas, about 200 to 1,500 psi 6 |
| Boosting along the line | Pumps, because dense CO2 behaves like a liquid 6 | Compressors 6 |
| Main release hazard | Asphyxiation and toxic effects; no ignition needed 1,7 | Fire, mainly jet fire and fireball in HSL's modeling 7 |
| Gas behavior after release | Vapor about 1.53 times heavier than air; settles and moves downhill 1 | Methane is buoyant and rises 7 |
| Internal corrosion driver | Free water forms an acid with CO2, so water content is kept low 6,7 | Water with CO2, oxygen, hydrogen sulfide or microbes 9 |
Sources: 49 CFR 192.3, 192.927, 195.2 3,9; PCOR technical brief (2011) 6; HSL and HSE (2009) 7; PHMSA (2022) 1.
What happens when CO2 is released?
CO2 becomes supercritical above about 31 °C (304 K) and 73.8 bar (about 1,070 psi), its critical point 8. When a pipeline fails, the pressure falls, the expanding fluid cools sharply and solid CO2 can form in the plume, which the UK Health and Safety Laboratory (HSL) noted makes dispersion hard to model 7.
The gas harms people without burning. PHMSA classes CO2 as an asphyxiant that displaces oxygen, with symptoms from headache and drowsiness up to confusion, rapid breathing and heart rhythm problems at higher exposure 1. Its report cites 40,000 parts per million (ppm) as immediately dangerous to life or health and 5,000 ppm as the occupational limit averaged over 8 hours 1. HSL added that rising CO2 threatens people well before falling oxygen does, and that a pure CO2 release gives little early warning to the senses 7.
In HSL's modeling of one pipeline carrying either fluid, CO2 released above 10 barg reached farther than natural gas at 7 barg, the UK threshold at which natural gas counts as a dangerous fluid 7. Natural gas hazards formed a circle around a fireball, while CO2 formed long, thin plumes downwind, and the toxic effect of CO2 gave much larger ranges than asphyxiation alone 7. At Satartia, responders first suspected a chlorine leak 1.
Which integrity threats are different for CO2?
- Internal corrosion. CO2 forms an acid solution with water, so dehydration is central; the 2011 brief gives a typical maximum water vapor content of 20 to 30 pounds per million standard cubic feet (lb/MMcf) 6,7. Oxygen in the stream can feed microbially influenced corrosion 6. Part 195 requires the CO2 to be compatible with the pipe and its components, and its corrosive effect to be investigated and mitigated 4.
- Running fractures. Part 195 requires CO2 pipelines to be designed to mitigate fracture propagation; the brief reports fracture arresters placed about every 1,000 feet 4,6.
- Cold and seals. HSL lists low temperatures after a release (a brittle fracture concern), very low viscosity that makes sealing harder, and sudden decompression damage to elastomer seals 7.
- Ground movement. At Satartia, PHMSA found that rain-saturated soil moved and put excessive axial load on the pipe until the girth weld failed 1.
Which rules apply to CO2 pipelines?
CO2 pipelines that could affect a high consequence area fall under the integrity management rule, 49 CFR 195.452 5. In May 2022, PHMSA announced a new rulemaking to update CO2 pipeline standards, including emergency preparedness and response, issued an updated nationwide advisory bulletin on land movement and geohazards, and proposed a civil penalty of $3,866,734 against the Satartia operator 2. This page does not track the rulemaking's later status.
Where integrity problems show up
| Decision | Data it depends on | What goes wrong without it | In the Library |
|---|---|---|---|
| Which areas a release could affect | Dispersion modeling that reflects terrain and heavier-than-air gas | Satartia, Mississippi, 2020: the model left the village outside the affected radius, so it was not a "could affect" high consequence area 1 | High consequence area |
| Whether geohazards are watched | Rainfall, slope movement, patrol findings | Same case: aerial patrols missed the hazard, and geohazard procedures in the operations and integrity programs were inadequate 1 | What is pipeline integrity management? |
| Whether local responders know what to expect | Contacts and information shared with emergency services | Same case: the operator did not notify local responders, who contacted it about 40 minutes after the rupture 1 | Consequence of failure |
| How dry the CO2 must be | Stream composition and water content | Free water with CO2 forms an acid that corrodes the pipe 6,7 | What is carbon dioxide (CO2) corrosion? |
| How a fracture will be stopped | Pipe toughness, wall and arrester spacing | Part 195 requires design against fracture propagation 4 | How are materials selected for oil and gas equipment? |
Sources: PHMSA failure investigation report (2022) 1; 49 CFR 195.111 4; PCOR (2011) 6; HSL and HSE (2009) 7.
Common questions
- Is CO2 flammable?
- No. It is an asphyxiant that displaces oxygen and is toxic at high concentrations.
- Does Part 195 cover all CO2 in pipelines?
- Its definition covers fluid of more than 90% CO2 molecules compressed to a supercritical state, in the eCFR text current to 22 October 2026.
- Is corrosion in CO2 pipelines the same as sweet corrosion?
- Both involve CO2 dissolved in water. See [What is carbon dioxide (CO2) corrosion?](/library/co2-corrosion/) and [Sweet vs sour corrosion: carbon dioxide vs hydrogen sulfide](/library/sweet-vs-sour-corrosion/).
Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.
Sources
- 1.Failure Investigation Report: Denbury Gulf Coast Pipelines, LLC, pipeline rupture and natural force damage, Satartia, Mississippi, February 22, 2020 · US Pipeline and Hazardous Materials Safety Administration (PHMSA)
- 2.PHMSA Announces New Safety Measures to Protect Americans From Carbon Dioxide Pipeline Failures (press release PHMSA 05-22) · US Pipeline and Hazardous Materials Safety Administration (PHMSA) ·
- 3.49 CFR 195.2, Definitions · eCFR, US Office of the Federal Register
- 4.49 CFR 195.4, 195.111 and 195.579 (compatibility, fracture propagation, internal corrosion control) · eCFR, US Office of the Federal Register
- 5.49 CFR 195.452, Pipeline integrity management in high consequence areas · eCFR, US Office of the Federal Register
- 6.CO2 Pipelines, Technical Brief (Plains CO2 Reduction Partnership) · Energy & Environmental Research Center, University of North Dakota, for the US DOE National Energy Technology Laboratory regional partnership
- 7.A comparison of hazard and risks for carbon dioxide and natural gas pipelines (J. Wilday, A. McGillivray, P. Harper, M. Wardman), IChemE Symposium Series No. 155, Hazards XXI · Health and Safety Laboratory and Health and Safety Executive (UK), Crown copyright, published by IChemE
- 8.Carbon dioxide: Phase change data (NIST Chemistry WebBook, SRD 69) · US National Institute of Standards and Technology (NIST)
- 9.49 CFR 192.3, Definitions, and 192.927 (internal corrosion direct assessment) · eCFR, US Office of the Federal Register