Skip to content
Beaconby Winda
FactCorrosion and Damage Mechanisms · Corrosion control

How do corrosion inhibitors work?

·10 sources

Short answer

A corrosion inhibitor is a chemical added in small amounts to a fluid to slow corrosion of the metal it wets. Most oilfield inhibitors are organic film formers that adsorb on steel and keep water away; related treatments remove oxygen or adjust pH. US hazardous liquid rules (49 CFR 195.579) require coupons or other monitoring to confirm they work.

By , Editor·Researched and drafted by ·Checked by , Editor·Last checked ·Next review

Why does it matter?

On August 19, 2000, a 30-inch natural gas pipeline ruptured beside the Pecos River near Carlsbad, New Mexico, and the fire killed 12 people camping nearby 3. The National Transportation Safety Board (NTSB) found severe internal corrosion, and recorded that no inhibitor was injected and no corrosion coupons were used in that section because the gas was not believed to be corrosive 3. It concluded that the corrosion was likely caused by microbes together with water, chlorides, oxygen, carbon dioxide (CO2) and hydrogen sulfide (H2S) that had collected at a low point 3.

How does a corrosion inhibitor work?

Inhibitors work in very small concentrations and can be added continuously or in batches to production fluids, acids, cooling water and other fluids 1. NASA's corrosion laboratory gives the additives in vehicle antifreeze as an everyday example 8. A 2023 open-access review describes four ways they act 1:

  • a thin adsorbed film that separates the metal from the water; 1,8
  • a chemically bonded passive layer on the surface; 1,8
  • a protective oxide film; 1,8
  • removal of an aggressive species from the fluid by binding it. 1,8

Most oilfield inhibitors are surfactants, similar in shape to soap molecules. A polar head bonds to the steel, and a long hydrocarbon tail, often 16 to 18 carbon atoms, faces the fluid and repels water 1. Protection lasts only while that film stays continuous, keeps its grip on the metal and re-forms as fluid flows past 1.

What types of inhibitors are used in oil and gas?

TypeHow it worksTypical useLimits noted in the sources
Organic film formers (amines, imidazolines, quaternary ammonium compounds, fatty acids)Adsorb on steel and form a water-repelling layerWell tubing, flowlines and pipelines carrying brine with CO2 or H2S 1Must stay stable across temperature, pressure and pH changes along a well 1
Inorganic inhibitorsForm passive or precipitated filmsMainly boilers and cooling towers rather than oilfield fluids 1Organic types dominate in oilfield systems 1
Oxygen scavengers (sulfite, bisulfite)Remove dissolved oxygenSystems where oxygen enters, such as water injection 1Inactive in acidic conditions, so injected with pH control agents 1
pH control agents and H2S scavengersReduce acidity or remove H2SWells producing aggressive gases 1Act on the fluid chemistry rather than the steel surface 1
Acidizing inhibitors with intensifiersProtect tubing and casing while acid is pumpedAcid stimulation of wells 1Cannot fully stop acid attack on steel 1
Vapor-phase inhibitorsEvaporate and act on surfaces in an enclosed spaceClosed systems and sealed packaging 7Need a closed environment 7

Sources: Solovyeva et al., 2023 1; NPL Guide No. 11 7.

How are inhibitors applied and checked?

Inhibitors are injected at chosen points so that the treated fluid carries them along the system 1,7. In US hazardous liquid and carbon dioxide pipelines, an operator that relies on inhibitors must use them in enough quantity to protect the whole part of the system they are meant to protect, and must use coupons or other monitoring equipment, examined at least twice each calendar year at intervals of no more than 7½ months (49 CFR 195.579) 4. Gas pipelines carrying corrosive gas must use coupons or other suitable means on the same schedule (49 CFR 192.477) 5.

Before field use, inhibitor films are tested on steel coupons under flow that mimics field conditions, measuring weight loss or electrochemical response 1. Common laboratory methods include static, wheel, bubble, rotating cylinder, rotating cage, impingement and flow loop tests, and ASTM G170 covers laboratory evaluation for multiphase systems 1. The UK Health and Safety Executive (HSE) research report RR1023 covers key performance indicators for inhibition and compares the inhibitor availability assumed at design with what is achieved in practice 2.

Dosing is not fixed for life. The UK National Physical Laboratory (NPL) notes that repairs or local changes can alter inhibitor needs, and that a pipe wall roughened by corrosion has more surface and can need more inhibitor 7.

What limits inhibitor performance?

  • Achievable rate. HSE reports that inhibitors can typically hold carbon steel exposed to CO2 or H2S to an inhibited rate of about 0.1 mm per year, largely regardless of the uninhibited rate 2.
  • Mechanisms they do not address. The same report finds inhibitors ineffective against oxygen corrosion and microbiologically influenced corrosion (MIC) 2. A 2023 review adds that many inhibitors have little effect on microbial growth and are combined with biocides 9.
  • Operating conditions. High flow rates, high temperatures, dissolved or suspended solids, and corrosion already present all reduce effectiveness 2.
  • Where they reach. Inhibitors act only on surfaces the treated fluid wets; PHMSA lists them alongside product quality control, internal coatings and line cleaning as internal controls 6. PHMSA also notes that operators usually prefer dewatering and chemical additives to internal pipe coatings 10.

Where integrity problems show up

Where it occurs (unit or equipment)Conditions that drive itHow it is usually foundIn the Library
Low point in a gas transmission line 3Water, chlorides, oxygen, CO2, H2S and microbes collected; no inhibitor, no coupons, and cleaning pigs could not run in that section 3Coupons or probes, in-line inspection, external wall thickness measurement, inspection when pipe is opened 3What is corrosion monitoring and which methods are used?
Inhibited hazardous liquid or carbon dioxide pipelinesDoses too small to protect every part of the system 4Coupons or other monitoring examined at least twice a year (49 CFR 195.579) 4Corrosion coupons vs electrical resistance (ER) probes
Deposits and biofilm in low-flow linesMicrobial activity, which inhibitors do not control 2,9Microbial testing of liquids and deposits from drips, scrubbers and pig receivers, as at Carlsbad 3How are biocides used to control microbiologically influenced corrosion?
Lines with high flow, solids or existing corrosionHigh flow, solids and existing corrosion reduce effectiveness; a roughened wall raises demand 2,7In-line inspection, hydrostatic testing or direct assessment 6What is in-line inspection (ILI) and pigging?

Sources: NTSB PAR-03/01 3; 49 CFR 195.579 4; HSE RR1023 2; PHMSA 6; NPL 7; Shi et al., 2023 9.

Common questions

Is a corrosion inhibitor the same as a biocide?
No. An inhibitor slows the corrosion reaction at the metal surface, while a biocide kills or suppresses microorganisms; HSE finds inhibitors ineffective against MIC. Some quaternary ammonium biocides also inhibit corrosion, which is why the two roles are sometimes confused.
What corrosion rate can an inhibitor achieve?
HSE reports about 0.1 mm per year as typically achievable for carbon steel in CO2 or H2S service; the report also compares the inhibitor availability assumed at design with what is achieved.
Do inhibitors replace corrosion-resistant alloys?
Not necessarily. The 2023 review notes that alloys cost several times more than coated carbon steel at the outset, and that the choice between alloys and coated carbon steel with inhibitors is weighed at well design on capital and operating cost.

Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.

Sources

  1. 1.Current Downhole Corrosion Control Solutions and Trends in the Oil and Gas Industry: A Review (V. A. Solovyeva, K. H. Almuhammadi, W. O. Badeghaish), Materials 16(5):1795 · MDPI (open access, CC BY 4.0) ·
  2. 2.RR1023: Reliable corrosion inhibition in the oil and gas industry (research report summary page) · UK Health and Safety Executive (HSE)
  3. 3.Pipeline Accident Report NTSB/PAR-03/01: Natural Gas Pipeline Rupture and Fire Near Carlsbad, New Mexico, August 19, 2000 · US National Transportation Safety Board (NTSB)
  4. 4.49 CFR 195.579, What must I do to mitigate internal corrosion? (Part 195, Subpart H) · eCFR, US Office of the Federal Register
  5. 5.49 CFR 192.475 to 192.477, Internal corrosion control (Part 192, Subpart I) · eCFR, US Office of the Federal Register
  6. 6.Fact Sheet: Internal Corrosion · US Pipeline and Hazardous Materials Safety Administration (PHMSA)
  7. 7.Guides to Good Practice in Corrosion Control No. 11: Corrosion control checklist · National Physical Laboratory (NPL), UK
  8. 8.Corrosion Control · NASA Kennedy Space Center, Corrosion Technology Laboratory
  9. 9.Comprehensive Review on the Use of Biocides in Microbiologically Influenced Corrosion (X. Shi, R. Zhang, W. Sand and others), Microorganisms 11(9):2194 · MDPI (open access, CC BY 4.0) ·
  10. 10.Fact Sheet: Pipe Coatings · US Pipeline and Hazardous Materials Safety Administration (PHMSA)