What is a crude distillation unit?
A crude distillation unit (CDU) heats desalted crude oil and splits it by boiling range into gases, naphtha, kerosene, gas oils and residue. It is the first major unit in a refinery: a fired heater brings the crude to about 650 to 750 °F (343 to 400 °C), and a vacuum column usually reprocesses the heaviest fraction.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked ·Next review
What does a crude distillation unit do?
The CDU sorts crude oil by boiling point without changing the molecules, which makes it a separation unit rather than a conversion unit 5. The US Department of Energy (DOE) puts the boiling span of crude components at about 90 °F (32 °C) to above 800 °F (427 °C), so one column can draw off several products at different heights 3.
According to the US Energy Information Administration (EIA), every refinery has atmospheric distillation, and more complex plants add a vacuum distillation unit (VDU) to process the residue from the atmospheric column 2. In 2012, about 80% of US refineries had a VDU 1.
How does crude oil move through the unit?
| Step | Equipment | Typical conditions 3 |
|---|---|---|
| 1. Desalting | Desalter: crude is mixed with wash water and the salty water settles out | Crude leaves at about 240 to 330 °F (115 to 150 °C) |
| 2. Preheat | Preheat train: heat exchangers recover heat from hot products and reflux streams | Crude reaches about 550 °F (288 °C) |
| 3. Fired heater | Direct-fired furnace | Outlet about 650 to 750 °F (343 to 400 °C) |
| 4. Flash zone | Partly vaporized crude enters the atmospheric column; vapor rises, liquid falls | All of the overhead and side products, plus 10 to 20% of the material below the flash zone, vaporize |
| 5. Column and strippers | Column with 30 to 50 trays near atmospheric pressure; small steam strippers clean up the side draws | Steam strips light ends and returns them to the column |
Salt is removed first because chloride salts foul equipment, corrode it and poison catalysts in downstream units. Desalting was once reserved for crudes with more than 10 pounds of salt per 1,000 barrels, but many refiners now desalt every crude 3. The top of the column is cooled by condensing the overhead vapor and returning part of the naphtha as reflux, with pumparound loops removing more heat lower down 4.
What products come off the crude column?
Published cut ranges differ from source to source. The ranges below come from one university course; for comparison, the US Chemical Safety and Hazard Investigation Board (CSB) report on Richmond described light gas oil there as boiling between 401 and 653 °F (205 to 345 °C) 8.
| Cut | Approximate boiling range (Penn State, 2020) | Typical next unit |
|---|---|---|
| Fuel gas and liquefied petroleum gas (LPG) | Lightest overhead material | Light ends unit, then gas treating |
| Full-range naphtha | Up to about 380 °F (193 °C) | Light naphtha to gasoline; heavy naphtha to a hydrotreater and catalytic reformer |
| Kerosene | About 380 to 480 °F (193 to 249 °C) | Hydrotreater, then jet fuel |
| Light gas oil | About 480 to 610 °F (249 to 321 °C) | Hydrotreater, then diesel |
| Heavy gas oil | About 610 to 690 °F (321 to 366 °C) | Fluid catalytic cracker or a thermal cracking unit |
| Atmospheric residue | Above the heavy gas oil cut | Vacuum distillation unit |
Source for ranges and next units: Penn State, FSC 432, Lesson 3 (2020) 5.
What does the vacuum distillation unit add?
Above about 750 °F (400 °C), oil begins to crack thermally, which upsets distillation and lays down coke 1,3. Lowering the pressure lowers the boiling points, so the residue can be split further without overheating it.
The atmospheric residue is reheated to about 700 to 800 °F (370 to 425 °C) and flashed into a column held at roughly 0.5 to 2 pounds per square inch absolute; steam ejectors or vacuum pumps hold the vacuum, and stripping steam helps the separation 6. DOE gives the operating range as about 10 to 40 millimeters of mercury (mmHg), compared with 760 mmHg at atmospheric pressure 3,1. Many vacuum columns use packing instead of trays to cut pressure drop 4.
The VDU makes light and heavy vacuum gas oils, which feed cracking units or become lubricant base stocks, and vacuum residue, which goes to a coker, visbreaker, deasphalter or the asphalt and fuel oil pools 3,4.
Where integrity problems show up
| Unit / equipment | Typical integrity issue | In the Library |
|---|---|---|
| Overhead condensers, piping and reflux drum | Hydrochloric acid formed when chloride salts hydrolyze in the heater; cracking of steel in wet hydrogen sulfide | Hydrochloric acid corrosion, Wet hydrogen sulfide damage |
| Overhead system with too little wash water | Ammonium chloride deposits that corrode once wetted | Ammonium chloride corrosion |
| Heater tubes, hot side-draw piping and towers above about 450 °F (232 °C) | Sulfidation that thins steel walls | Sulfidation, Richmond refinery fire (2012) |
| Atmospheric tower, vacuum heater and vacuum tower | Organic (naphthenic) acid attack above about 450 °F | Naphthenic acid corrosion |
Sources: Occupational Safety and Health Administration (OSHA) Technical Manual, Section IV, Chapter 2 (undated) 7; CSB, Richmond final report (2015) 8.
At Richmond in 2012, an 8-inch carbon steel line carrying light gas oil from the atmospheric column, at about 10,800 barrels per day, ruptured after sulfidation thinned it 8. The CSB states that sulfidation acts between about 450 and 1,000 °F (232 to 538 °C) and occurs at every refinery that runs crude. It also found that over 95% of the 144 US refineries of that time were built before 1985, so much original carbon steel piping may have widely varying silicon content and corrosion rates 8.
Common questions
- What is the difference between a crude distillation unit and a vacuum distillation unit?
- The CDU works near atmospheric pressure and takes off everything up to heavy gas oil. The VDU takes the CDU's residue and distills it again under deep vacuum, so the heavy gas oils can boil off without cracking (DOE, 2006; EIA, 2012).
- Why is crude oil desalted before distillation?
- Chloride salts in crude break down into hydrochloric acid when heated and also foul exchangers and poison catalysts. Desalting removes most of the salt before the preheat train (DOE, 2006; OSHA, undated).
- Does the crude unit change the oil chemically?
- It is designed not to. Distillation is a physical separation, and heater temperatures are capped near 750 °F to avoid cracking (Penn State, 2020; EIA, 2012).
Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.
Sources
- 1.Vacuum distillation is a key part of the petroleum refining process · U.S. Energy Information Administration, Today in Energy ·
- 2.Refining crude oil: the refining process · U.S. Energy Information Administration
- 3.Energy Bandwidth for Petroleum Refining Processes · U.S. Department of Energy, Industrial Technologies Program (prepared by Energetics Inc.)
- 4.FSC 432 Petroleum Refining, Lesson 4: Atmospheric and Vacuum Distillation Units · Penn State College of Earth and Mineral Sciences (S. Eser)
- 5.FSC 432 Petroleum Refining, Lesson 3: Overall Refinery Flow · Penn State College of Earth and Mineral Sciences (S. Eser)
- 6.AP-42, Section 5.1: Petroleum Refining · U.S. Environmental Protection Agency
- 7.OSHA Technical Manual, Section IV, Chapter 2: Petroleum Refining Processes · Occupational Safety and Health Administration
- 8.Final Investigation Report: Chevron Richmond Refinery Pipe Rupture and Fire, Report No. 2012-03-I-CA · U.S. Chemical Safety and Hazard Investigation Board