What is ammonium chloride corrosion?
Ammonium chloride corrosion is attack on steel beneath ammonium chloride salt, which forms when ammonia and hydrogen chloride meet in a cooling stream. The salt absorbs moisture and becomes a strongly corrosive film. It occurs in crude unit overheads and hydroprocessing effluent coolers; API RP 932-B covers the latter.
By Jun Zhong, Editor·Researched and drafted by Beacon's AI newsroom·Checked by Jun Zhong, Editor·Last checked ·Next review
Why does it matter?
The ammonia added to a crude unit overhead to neutralize hydrochloric acid can itself react with hydrogen chloride (HCl) and form ammonium chloride (NH4Cl) salt, and OSHA notes that these deposits can cause serious corrosion if too little wash water is injected 1. A 2021 case study of a crude tower in the Kurdistan Region of Iraq illustrates the result. The unit had no desalter, salt in its crude feed stayed above 119 pounds per thousand barrels (PTB) through 2020 and reached 355 PTB in March, and inspection found top trays perforated with ammonia salts on the walls 2. The authors attributed the damage to combined ammonium chloride and HCl corrosion 2.
How does ammonium chloride form and why does it corrode?
Chloride salts in crude break down on heating and release HCl, while ammonia arrives with desalter wash water or is injected as a neutralizer 2. In catalytic reformers, HCl can also come from the hydrogenation of chlorine compounds 1. When the gas mixture cools, the two react and the salt drops out as a solid. The temperature at which this happens depends on the partial pressures of ammonia and HCl 2.
The salt can form while the stream is still above the water dew point, so it lands on metal that is otherwise dry 2. Ammonium chloride is hygroscopic: it pulls water vapor out of the gas. In 2023 laboratory tests at 25% water vapor by volume and 70 to 160 °C (158 to 320 °F), carbon steel under the salt corroded heavily once water was taken up, and both water uptake and corrosion started at relative humidity well below the level at which the salt fully dissolves 3. Iron chlorides built up next to the steel as the attack went on 3.
The damage is local. The wet salt breaks down the oxide layer and produces rapid thinning and pits 4. A failure analysis of a sour water stripper found perforation caused by pitting, with iron chloride as the corrosion product; in that study's laboratory tests, the corrosion rate of the stripper's carbon steel rose from about 1.6 to 7.2 mm per year as salt concentration increased from 5% to 20% 5. Deposits also foul equipment, cutting heat transfer and raising pressure drop 4.
Where does ammonium chloride corrosion occur?
- Crude unit overheads and tower tops. OSHA names overhead ammonium chloride deposits as a cause of serious corrosion and notes that wetted neutralized salts corrode crude unit equipment 1.
- Hydroprocessing reactor effluent air coolers (REACs). Salt settles on the tubes as the effluent cools and is worst at the inlet and front rows, where temperature gradients are steep and flow is complex; reported failures include perforated tube bundles, leaks and unplanned shutdowns 4. API RP 932-B (3rd edition, June 2019) gives design, materials, operation and inspection guidance for these systems, which are prone to ammonium chloride and ammonium bisulfide salts 6.
- Catalytic reformers. The salt can form in pretreater exchangers and foul the stabilizer 1.
- Sour water strippers and other units. Researchers report ammonium chloride damage in stripper top systems and in crude distillation, hydrotreating and catalytic cracking units 5.
- Outside refining. In boilers burning biomass or waste, the salt forms at the cold end when flue gas carries both HCl and unreacted ammonia, and it corrodes air preheaters 3.
How is ammonium chloride corrosion controlled and found?
The case study groups control into three approaches 2. The first lowers the salt formation temperature by cutting HCl and ammonia, mainly through better desalting and by removing outside ammonia sources; the study reports that chloride above 20 ppm in desalted crude can lead to significant overhead corrosion and fouling. The second keeps equipment hotter than the salt formation temperature where that is feasible. The third, once salt has formed, is a well-distributed water wash with enough excess water that it does not all evaporate, typically 10% to 25% by volume, plus limiting neutralizing ammonia to what drum water pH control needs 2.
In laboratory work on air cooler tubes, water injection removed salt deposits better at higher gas velocity, temperature and injection rate, while earlier field studies tied poorly placed injection or poor flow to worse corrosion 4.
Finding the damage relies on several signals 2,4:
- Chloride and ammonia measured in the overhead drum water, used to estimate the salt formation temperature 2.
- Falling heat transfer and rising pressure drop in coolers 4.
- Internal inspection and deposit analysis during shutdowns, as in the 2021 case 2.
Inspection guidance allows piping thickness to be tracked at a small number of fixed points, on the basis that for most mechanisms a whole circuit loses metal at a similar rate 7. Ammonium chloride attack is local and sits under deposits 4. API RP 571 (3rd edition, March 2020) covers over 60 refinery damage mechanisms, with inspection method guidelines for each 6.
Where integrity problems show up
| Where it occurs (unit or equipment) | Conditions that drive it | How it is usually found | In the Library |
|---|---|---|---|
| Crude tower top trays and overhead line | Ammonia and HCl in the vapor; salt forming above the water dew point; too little wash water 1,2 | Internal inspection and deposit analysis at shutdown; chloride and ammonia in overhead drum water 2 | What is a crude distillation unit? |
| Reactor effluent air cooler tubes, inlet and front rows | Salt dropping out as hydroprocessing effluent cools; steep temperature gradients 4 | Loss of heat transfer, higher pressure drop, tube leaks 4; inspection plan in API RP 932-B 6 | What is hydroprocessing (hydrotreating and hydrocracking)? |
| Reformer pretreater exchangers and stabilizer | HCl from chlorine compounds meeting ammonia 1 | Exchanger and stabilizer fouling 1 | What are the main types of heat exchangers in process plants? |
| Sour water stripper top trays and piping | Salt on carbon steel in the stripper overhead 5 | Failure analysis of perforations: pits with iron chloride product 5 | What is pitting corrosion? |
| Any circuit tracked at a few thickness points | Local attack under salt deposits 4 | Fixed-point thickness readings, which assume a circuit thins evenly 7 | What are condition monitoring locations (CMLs)?, How does ultrasonic thickness measurement work? |
Sources: OSHA Technical Manual, Section IV, Chapter 2 1; Ahmed, 2021 2; Liu et al., 2026 4; Jin et al., 2024 5; API 2025 catalog 6; CSB Report 2012-03-I-CA, 2015 7.
Common questions
- Is ammonium chloride corrosion the same as hydrochloric acid corrosion?
- They are linked but not the same. HCl attacks where it dissolves in condensed water, while ammonium chloride is the salt that HCl forms with ammonia, often before any water condenses.
- How is it different from ammonium bisulfide corrosion?
- Ammonium bisulfide forms from ammonia and hydrogen sulfide and, according to OSHA, causes serious corrosion below the water dew point in hydroprocessing. API RP 932-B addresses both salts in reactor effluent systems.
- Do nickel alloys or stainless steels stop it?
- Not always. In the 2021 case study, trays made of nickel-copper alloy 400 and of 410 stainless steel were both badly perforated under heavy salt loading.
Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.
Sources
- 1.OSHA Technical Manual, Section IV, Chapter 2: Petroleum Refining Processes · US Occupational Safety and Health Administration (OSHA)
- 2.Corrosion in Crude Oil Distillation Unit Overhead: A Recent Case Study (A. A. Ahmed), ARO The Scientific Journal of Koya University 9(1) · Koya University ·
- 3.Cold-end corrosion caused by hygroscopic ammonium chloride in thermal conversion of biomass and waste (E. Vainio, P. Yrjas, L. Hupa, M. Hupa), Fuel 346, 128061 · Åbo Akademi University (research portal record, CC BY) ·
- 4.Experimental Study on Water Injection Removal of Ammonium Chloride Particles to Enhance Hydrotreatment Air Cooler Reliability (X. Liu et al.), Fuels 7, 33 · MDPI (CC BY) ·
- 5.Study on Corrosion Behavior of Sour Water Stripper in Ammonium Chloride by Electrochemical Techniques (S. Jin, G. Chen, X. Huang, G. Ou), Archives of Metallurgy and Materials 69(2), 507-513 · Polish Academy of Sciences (CC BY-NC 4.0)
- 6.2025 Publications Catalog (entries for RP 932-B and RP 571) (RP 932-B, 3rd edition, June 2019; RP 571, 3rd edition, March 2020) · American Petroleum Institute (API)
- 7.Final Investigation Report: Chevron Richmond Refinery Pipe Rupture and Fire (Report 2012-03-I-CA) · US Chemical Safety and Hazard Investigation Board (CSB)