Skip to content
Beaconby Winda
FactAsset Integrity Management · Integrity management systems

What are safety and environmental critical elements (SECEs)?

·10 sources

Short answer

Safety and environmental critical elements (SECEs) are parts of an installation whose failure could lead to a major accident, or that prevent or limit one. They include software and equipment needed only in emergencies. The UK Offshore Installations (Offshore Safety Directive) (Safety Case etc) Regulations 2015 (SCR 2015) define them and require a verification scheme for them.

By , Editor·Researched and drafted by ·Checked by , Editor·Last checked ·Next review

Why does it matter?

At a Torrance, California, refinery in February 2015, a slide valve that the plant relied on as a safety-critical safeguard had eroded during six years of service until it could no longer seal; hydrocarbons flowed back through the unit into an electrostatic precipitator, a pollution control device, and exploded 1. The US Chemical Safety and Hazard Investigation Board (CSB) found that equipment had been run past its predicted safe operating life and that the refinery relied on safeguards it could not verify, including the valve's ability to seal 1. It recommended that refineries state each safety-critical device's safety function, the consequence of its failure, how it is tested and its target availability, for every mode of operation 2. The UK offshore regime covers similar ground: SECEs are identified from major accident scenarios, and their performance standards describe function, survivability, reliability and availability 4,6.

Where does the term come from?

SCR 2015 came into force on 19 July 2015 for oil and gas operations in UK external waters, replacing the 2005 Safety Case Regulations there; the earlier rules used the term safety-critical elements (SCEs) 4. The 2015 rules extended verification to environmental as well as safety-critical elements, and guidance from the UK Health and Safety Executive (HSE) expects that former SCEs will usually be SECEs 4. The safety case regime itself builds on Lord Cullen's central recommendation after the Piper Alpha disaster: every offshore operator or owner must prepare a safety case for the regulator to accept 4. Amendments in force from 6 April 2026 (S.I. 2026/185) added definitions so that the regulations also address carbon capture, utilization and storage (CCUS) and offshore hydrogen operations 3.

How are SECEs identified?

  • From the major accident scenarios in the safety case. HSE's guidance on the regulations (L154) says identification should follow from the major accident hazards and the meaning of major accident 4.
  • Systematically, down to component level. Within a critical system some parts are SECEs and others are not; parts that would not start an accident but would add significantly to a chain of events also count 4.
  • Including detection, control and mitigation systems, and items that add redundancy or diversity 4.
  • As a list that changes over time, for example when temporary equipment arrives for a limited activity 4.
  • Owned by the dutyholder. The dutyholder must keep a written record of SECEs; the verifier comments on it but does not assess the identification method in detail 3,4.

What is a performance standard for an SECE?

HSE's Key Programme 3 handbook describes a performance standard as a statement, in words or numbers, of how a system, item, person or procedure must perform, used to plan, measure, control and audit the hazard over the installation's life 6. Such standards are often written in terms of functionality, survivability, reliability and availability 6. Measurable examples given by HSE are the maximum closure time of a valve and its maximum allowable leak rate 5. See Performance standard (for safety-critical elements).

How are SECEs verified and kept in good condition?

Regulation 9 of SCR 2015 requires a verification scheme to show that SECEs are or will be suitable and, once provided, stay in good repair and condition 4. A verifier who is independent and competent examines and tests the elements, reviews designs, certificates and work in progress, and reports findings and recommended remedial action; the dutyholder must act on reports and record what it did 3,4. For a new production installation the scheme must exist before design is complete 4.

HSE's 2004 to 2007 inspections of nearly 100 offshore installations, Key Programme 3 (KP3), found maintenance of SCEs among the weakest areas, together with backlog, deferrals and measuring compliance with performance standards 5. HSE's position was that the target for safety-critical maintenance backlog should be zero hours 5.

Where integrity problems show up

DecisionData it depends onWhat goes wrong without itIn the Library
Listing the SECEsMajor accident scenarios and the part each system plays in themCompanies often treated degraded utility and other non-critical plant as low priority, not seeing how it can weaken SECEs in an accident 5Asset integrity vs reliability vs asset performance management
Writing performance standardsMeasurable criteria, such as valve closure time and leak rateGeneric standards and work orders without acceptance criteria left managers unable to tell whether SECEs met their standards 5Performance standard (for safety-critical elements)
Choosing how to testA full-loop test from detector to final elementTemporary refuge ventilation shutdowns were often tested piecemeal; 64% of HSE's tests on them scored red or amber 5What is a safety instrumented system (SIS)?
Inspecting and choosing materials for firewater deluge pipeworkCorrosion findings and nozzle condition10 of 20 deluge systems tested scored red or amber, often because corroded carbon steel pipework blocked pipes and nozzles 5What is corrosion?
Running a safety-critical item past its planned intervalDegradation history and safe operating lifeAt Torrance in 2015, an eroded slide valve could not seal when it was needed as a barrier 1How are inspection intervals set for vessels, piping and tanks?
Managing ageing SECEsCondition trends over timeHSE found installation age is not a reliable guide to condition, so ageing management relies on knowing how SECE condition is changing 7What is asset life extension?

Sources: HSE KP3 report, 2007 5; CSB Torrance report, 2017 1; HSE Key Programme 4 (KP4) report, 2014 7.

Common questions

What is the difference between an SCE and an SECE?
SCE is the term used under the 2005 Safety Case Regulations; SECE is the 2015 term, which adds elements critical to preventing major environmental incidents. HSE expects former SCEs will usually be SECEs.
Is a safety instrumented system an SECE?
It can be one, but SECEs are wider: HSE's guidance covers any structure, plant, equipment, system, software or component meeting the definition. See [What is a safety instrumented system (SIS)?](/library/safety-instrumented-system/).
Do US rules use the same idea?
They cover similar ground under mechanical integrity. Process safety rules list pressure vessels and tanks, piping, relief and vent systems, emergency shutdown systems, controls and pumps, and offshore rules cover equipment and systems that prevent or mitigate uncontrolled releases.
Is a performance standard a legal requirement?
HSE's KP3 handbook notes that the safety case rules do not specifically require performance standards, but performance requirements still need to be set for each element, and missing a standard is not by itself a breach of law. The Energy Institute's guidelines (3rd edition, January 2020) cover developing performance standards and assuring SECEs.

Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.

Sources

  1. 1.Investigation Report: ExxonMobil Torrance Refinery Electrostatic Precipitator Explosion, Torrance, California (Report No. 2015-02-I-CA) · US Chemical Safety and Hazard Investigation Board (CSB)
  2. 2.ExxonMobil Torrance Refinery Explosion (investigation page, recommendation status summaries) · US Chemical Safety and Hazard Investigation Board (CSB)
  3. 3.The Offshore Installations (Offshore Safety Directive) (Safety Case etc.) Regulations 2015 (S.I. 2015/398), regulation 2 (as amended) · legislation.gov.uk, The National Archives
  4. 4.L154, The Offshore Installations (Offshore Safety Directive) (Safety Case etc) Regulations 2015: Guidance on Regulations (First edition) · UK Health and Safety Executive (HSE)
  5. 5.Key Programme 3: Asset Integrity Programme · UK Health and Safety Executive (HSE), Offshore Division
  6. 6.KP3 Project Handbook (abbreviated version) · UK Health and Safety Executive (HSE), Offshore Division
  7. 7.Key Programme 4 (KP4): Ageing and life extension programme · UK Health and Safety Executive (HSE), Energy Division
  8. 8.29 CFR 1910.119, Process safety management of highly hazardous chemicals, paragraph (j) Mechanical integrity · eCFR, US Office of the Federal Register
  9. 9.30 CFR 250.1916, What criteria for mechanical integrity must my SEMS program meet? · eCFR, US Office of the Federal Register