How does cathodic protection work?

·10 sources

Short answer

Cathodic protection (CP) controls corrosion of buried or submerged metal by making the whole surface a cathode. It uses sacrificial anodes of a more active metal or direct current fed through inert anodes from a rectifier. US rules require coating plus CP on most buried steel pipelines built since the early 1970s (49 CFR 192 Subpart I, 195 Subpart H).

By , Editor·Researched and drafted by ·Checked by , Editor·Last checked ·Next review

Why does it matter?

On 11 December 2012, a buried 20-inch gas transmission pipeline ruptured near Sissonville, West Virginia; the fire destroyed three houses 1. The line was coated and under impressed current CP, and readings at the nearest test station, about 100 feet away, had been satisfactory for 10 years 1. The National Transportation Safety Board (NTSB) found that coarse rock backfill had damaged the coating and blocked the protective current, so more than 30 square feet of pipe corroded, losing over 70% of the wall at the worst point 1. Current that cannot reach the bare steel cannot protect it 1.

How does cathodic protection work?

Corrosion removes metal only at anodic areas (see What is corrosion?). CP connects an external anode to the structure and drives direct current through the soil or water onto the entire surface, so every area becomes a cathode and the metal-dissolving reaction is suppressed 3,10. NASA's laboratory illustration is a zinc strip wired to copper in acid: the zinc corrodes faster while the copper stops corroding 9.

CP is normally paired with a coating. The coating is the first barrier; CP protects steel exposed at coating flaws and damage 1,5. A good coating also cuts the current needed and lets it travel further: the UK National Physical Laboratory (NPL) notes that one impressed current station can protect up to 150 km of very well coated pipeline, while bare pipe may need stations less than 2 km apart 3.

CP protects the outside of pipelines, tank bases, ship hulls, jetties, piles and offshore structures, and the inside of large pipes, tanks and water systems 3. It needs a continuous electrolyte, so it cannot prevent atmospheric corrosion 3,4.

What is the difference between sacrificial anode and impressed current systems?

Sacrificial (galvanic) anodesImpressed current
Source of currentNatural potential difference between the anode metal and steel 3External direct current source, usually a transformer rectifier 3
AnodesMagnesium, zinc or aluminum alloys that are consumed 3Low-dissolution anodes: graphite, magnetite, high-silicon iron, or titanium coated with mixed metal oxides 3
Driving voltageAbout 0.5 V for zinc and aluminum, up to about 1 V for magnesium 3Adjustable, up to about 50 V 3
Typical useSmall or well-coated structures, local protection, offshore platforms; zinc and aluminum mainly in sea water, magnesium in soil 3Long pipelines and large or poorly coated structures 3
Effect on neighborsLow interference risk 3Must be designed to limit stray current on nearby structures 3,6

The two can share one structure, for example anodes that protect a line until its rectifier is switched on, but then the design has to keep them from interfering with each other 3. The deeper comparison is in Sacrificial anode vs impressed current cathodic protection; see also Sacrificial anode and Impressed current cathodic protection.

How is cathodic protection checked?

Protection is judged from the potential between the structure and a reference electrode placed in the electrolyte, often called the pipe-to-soil potential; copper/copper sulfate electrodes are used in soil and silver/silver chloride in sea water 3,7.

US gas pipeline rules (49 CFR 192.463) require CP to meet at least one criterion in Appendix D to Part 192 6. For steel, the first reads: "A negative (cathodic) voltage of at least 0.85 volt, with reference to a saturated copper-copper sulfate half cell." 7 The others, in summary, are a negative shift of at least 300 mV with current applied (for steel not in contact with other metals), at least 100 mV of polarization measured by switching the current off and watching the decay, a test based on the polarization curve, and a measured net current flowing into the steel at known anodic points 7. Voltage drops in the soil must be allowed for when reading a potential 7. Liquid pipelines follow the criteria of NACE SP0169-2007, incorporated by reference in 49 CFR 195.571 and 195.3 8.

Monitoring under 49 CFR 192.465 includes 6:

  • a test of each protected pipeline once each calendar year, at intervals of no more than 15 months; 6
  • an inspection of each rectifier six times a year, at intervals of no more than 2½ months; 6
  • for onshore gas transmission lines with systemic low readings, close interval surveys at about 5-foot spacing in both directions from the low test station. 6

What can cathodic protection not do?

  • Reach shielded steel. Rocks, roots and disbonded coating can block the current 1. At Marshall, Michigan, in 2010, pipe-to-soil readings were above the federal minimum, but the cracks that failed had grown under disbonded tape, which can keep the current off the steel 2.
  • Protect where there is no electrolyte. It does not stop atmospheric corrosion, and an internal anode seldom spreads protection more than two to five pipe diameters, so it is not usually practical for small-bore piping 3.
  • Be applied without limits. The amount must not damage the coating or pipe 6. Excessive negative potentials can loosen coatings, attack aluminum and lead, and drive hydrogen into high-strength steel 3,10.
  • Avoid affecting nearby structures by itself. A nearby metal structure can pick up the current and corrode where it leaves, which is called stray current or interference 3,6.

Where integrity problems show up

Where it occurs (unit or equipment)Conditions that drive itHow it is usually foundIn the Library
Buried coated pipelines in rocky groundRock backfill damages the coating and shields steel from CP current 1Not by test-station readings alone; the Sissonville readings had passed for 10 years 1Soil corrosion, In-line inspection
Tape-coated liquid pipelinesDisbonded tape lets water reach the steel but blocks current; cracks grow in corroded areas 2A 2005 in-line crack inspection had reported crack-like features over the later rupture area 2Pipeline stress corrosion cracking, After an in-line inspection run
Pipelines near high-voltage AC power linesAlternating current (AC) interference; AC corrosion at very small coating holidays in low-resistivity soil 10Interference surveys when potentials shift or new power lines or pipelines appear 6Coating holiday, Pipe-to-soil potential
Impressed current systemsRectifier output lost or reduced 6Rectifier inspections six times a year, remotely or on site 6Impressed current cathodic protection
High-strength steel under strong CPHydrogen from the cathodic reaction embrittling the steel 3,10Potential measurements; 192.463(c) requires the CP level to be kept below what damages coating or pipe 6Hydrogen embrittlement

Sources: NTSB PAR-14/01 1; NTSB PAR-12/01 2; NPL Guide No. 1 3; 49 CFR 192.463, 192.465, 192.473 6; UFGS 26 42 17 10.

Common questions

Does cathodic protection protect the inside of a pipe?
Generally not. The Pipeline and Hazardous Materials Safety Administration (PHMSA) notes it is not used against corrosion caused by a pipeline's contents, and NPL lists internal uses only for large-diameter lines, tanks and water systems.
Is a good coating enough on its own?
No. US rules require both a coating and CP on buried steel gas lines installed after July 31, 1971, and CP is what protects the steel at coating flaws.
Can there be too much cathodic protection?
Yes. Overprotection can disbond coatings and cause hydrogen embrittlement, and federal rules require the level to be controlled.

Beacon explains these concepts in its own words for education. It does not reproduce or replace the standards cited, and Winda is not affiliated with or endorsed by the organizations that publish them. Engineering decisions need the current edition of the standard and a qualified engineer.

Sources

  1. 1.Pipeline Accident Report NTSB/PAR-14/01: Columbia Gas Transmission Corporation Pipeline Rupture, Sissonville, West Virginia, December 11, 2012 · US National Transportation Safety Board (NTSB)
  2. 2.Pipeline Accident Report NTSB/PAR-12/01: Enbridge Incorporated Hazardous Liquid Pipeline Rupture and Release, Marshall, Michigan, July 25, 2010 · US National Transportation Safety Board (NTSB)
  3. 3.Guides to Good Practice in Corrosion Control No. 1: Cathodic Protection (D. W. Harvey) · National Physical Laboratory (NPL), UK
  4. 4.Fact Sheet: Cathodic Protection · US Pipeline and Hazardous Materials Safety Administration (PHMSA)
  5. 5.Fact Sheet: External Corrosion · US Pipeline and Hazardous Materials Safety Administration (PHMSA)
  6. 6.49 CFR 192.455, 192.461, 192.463, 192.465 and 192.473 (Subpart I, Requirements for Corrosion Control) · eCFR, US Office of the Federal Register
  7. 7.Appendix D to Part 192, Criteria for Cathodic Protection and Determination of Measurements · eCFR, US Office of the Federal Register
  8. 8.49 CFR 195.571 and 195.3 (incorporation by reference of NACE SP0169-2007) · eCFR, US Office of the Federal Register
  9. 9.Corrosion Fundamentals · NASA Kennedy Space Center, Corrosion Technology Laboratory
  10. 10.UFGS 26 42 17, Impressed Current Cathodic Protection (ICCP) System · US Army Corps of Engineers, NAVFAC and AFCEC (Unified Facilities Guide Specifications), via WBDG